A three-dimensional computational analysis of fluid-structure interaction in the aortic valve

被引:283
作者
De Hart, J [1 ]
Peters, GWM [1 ]
Schreurs, PJG [1 ]
Baaijens, FPT [1 ]
机构
[1] Eindhoven Univ Technol, Dept Biomed Engn, NL-5600 MB Eindhoven, Netherlands
关键词
aortic valve; fluid-structure interaction; finite element method; fictitious domain method; three-dimensional analysis;
D O I
10.1016/S0021-9290(02)00244-0
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Numerical analysis of the aortic valve has mainly been focused on the closing behaviour during the diastolic phase rather than the kinematic opening and closing behaviour during the systolic phase of the cardiac cycle. Moreover, the fluid-structure interaction in the aortic valve system is most frequently ignored in numerical modelling. The effect of this interaction on the valve's behaviour during systolic functioning is investigated. The large differences in material properties of fluid and structure and the finite motion of the leaflets complicate blood-valve interaction modelling. This has impeded numerical analyses of valves operating under physiological conditions. A numerical method, known as the Lagrange multiplier based fictitious domain method, is used to describe the large leaflet motion within the computational fluid domain. This method is applied to a three-dimensional finite element model of a stented aortic valve. The model provides both the mechanical behaviour of the valve and the blood flow through it. Results show that during systole the leaflets of the stented valve appear to be moving with the fluid in an essentially kinematical process governed by the fluid motion. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:103 / 112
页数:10
相关论文
共 26 条
  • [1] Baaijens FPT, 2001, INT J NUMER METH FL, V35, P743, DOI 10.1002/1097-0363(20010415)35:7<743::AID-FLD109>3.0.CO
  • [2] 2-A
  • [3] A 3-DIMENSIONAL ANALYSIS OF A BIOPROSTHETIC HEART-VALVE
    BLACK, MM
    HOWARD, IC
    HUANG, X
    PATTERSON, EA
    [J]. JOURNAL OF BIOMECHANICS, 1991, 24 (09) : 793 - &
  • [4] BREZZI F, 1974, REV FR AUTOMAT INFOR, V8, P129
  • [5] A three-dimensional mechanical analysis of a stentless fibre-reinforced aortic valve prosthesis
    Cacciola, G
    Peters, GWM
    Schreurs, PJG
    [J]. JOURNAL OF BIOMECHANICS, 2000, 33 (05) : 521 - 530
  • [6] CACCIOLA G, 1998, THESIS EINDHOVEN U T
  • [7] Caro C. G., 1978, MECH CIRCULATION
  • [8] STRESS-DISTRIBUTION ON THE CUSPS OF A POLYURETHANE TRILEAFLET HEART-VALVE PROSTHESIS IN THE CLOSED POSITION
    CHANDRAN, KB
    KIM, SH
    HAN, G
    [J]. JOURNAL OF BIOMECHANICS, 1991, 24 (06) : 385 - 395
  • [9] Cuvelier C, 1986, FINITE ELEMENT METHO
  • [10] A two-dimensional fluid-structure interaction model of the aortic value
    De Hart, J
    Peters, GWM
    Schreurs, PJG
    Baaijens, FPT
    [J]. JOURNAL OF BIOMECHANICS, 2000, 33 (09) : 1079 - 1088