Electromagnetic Interference of Communication Devices on ECG Machines

被引:40
作者
Baranchuk, Adrian [1 ]
Kang, Jaskaran [1 ]
Shaw, Cathy [1 ]
Campbell, Debra [1 ]
Ribas, Sebastian [2 ]
Hopman, Wilma M. [1 ]
Alanazi, Haitham [1 ]
Redfearn, Damian P. [1 ]
Simpson, Christopher S. [1 ]
机构
[1] Queens Univ, Kingston Gen Hosp, Arrhythmia Serv, Kingston, ON K7L 2V7, Canada
[2] McMaster Univ, Dept Cardiol, Hamilton, ON, Canada
关键词
ATRIAL-FIBRILLATION; TELEPHONE; PHONES;
D O I
10.1002/clc.20459
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Use of communication devices in the hospital environment remains controversial. Electromagnetic interference (EMI) can affect different medical devices. Potential sources for EMI on ECG machines were systematically tested. Hypothesis: Communication devices produce EMI on ECG machines. EMI impairs ECG interpretation. Methods: The communication devices tested were: a global system for mobile communication (GSM) receiver, a code division multiple access (CDMA) receiver, an analog phone, a wireless local area network, and an alpha-numeric pager. EMI was tested on 3 ECG machines: MAC 5000, MAC 1200, and ELI 100. The devices were tested at 2 and 1 meter, 50, 25, and 0 cm from the acquisition module. The ECGs were presented to a heterogeneous group of clinical providers, (medical students, residents, nurses, industry representatives from cardiac devices companies, and attending cardiologists) to evaluate the impact of EMI on ECG interpretation skills. Results: EMI was detected on the MAC 5000 ECG machine when activated GSM, CDMA, and analog phones were placed on top of the acquisition module. No EMI was seen on the other ECG machines or when phones were at a longer distance or deactivated. EMI was incorrectly diagnosed in 18% of the cases. EMI was confused most frequently with atrial fibrillation or flutter (52%), ventricular arrhythmias (22%), and pacemaker dysfunction (26%). Medical students (p<0.003) and non-cardiology residents (p = 0.05) demonstrated significantly worse performance on EMI interpretation. Conclusions: Digital and analog phones produce EMI on modern ECG machines when activated in direct contact to the acquisition module. EMI impairs ECG interpretation.
引用
收藏
页码:588 / 592
页数:5
相关论文
共 16 条
[1]  
ALTAMURA G, 1997, EUR HEART J, V18, P1532
[2]  
BARANCHUK A, 2008, CRIT CARE N IN PRESS
[3]   Interference of electrocardiographic recordings by a mobile telephone [J].
Brodlie, Malcolm ;
Robertson, Daniel ;
Wyllie, Jonathan .
CARDIOLOGY IN THE YOUNG, 2007, 17 (03) :328-329
[4]   Causes of errors in the electrocardiographic diagnosis of atrial fibrillation by physicians [J].
Davidenko, Jorge Mario ;
Snyder, Lisa Simonetta .
JOURNAL OF ELECTROCARDIOLOGY, 2007, 40 (05) :450-456
[5]   Oral anticoagulation for ECG tremor artefact simulating atrial fibrillation [J].
Finsterer, J ;
Stöllberger, C ;
Gatterer, E .
ACTA CARDIOLOGICA, 2003, 58 (05) :425-429
[6]   Mobile communication regulations updated: how safely are doctors' telephones used? [J].
Kidd, AG ;
Sharratt, C ;
Coleman, J .
QUALITY & SAFETY IN HEALTH CARE, 2004, 13 (06) :478-478
[7]   Mobile phones in the hospital - past, present and future [J].
Klein, AA ;
Djaiani, GN .
ANAESTHESIA, 2003, 58 (04) :353-357
[8]   Clinical consequences of electrocardiographic artifact mimicking ventricular tachycardia [J].
Knight, BP ;
Pelosi, F ;
Michaud, GF ;
Strickberger, SA ;
Morady, F .
NEW ENGLAND JOURNAL OF MEDICINE, 1999, 341 (17) :1270-1274
[9]  
*MED DEV AG, 1997, DEV B DEP HLTH
[10]  
Mitchell AR, 2003, BMJ-BRIT MED J, V326, P140