Development of an intraoperative gamma camera based on a 256-pixel mercuric iodide detector array

被引:15
作者
Patt, BE [1 ]
Tornai, MP [1 ]
Iwanczyk, JS [1 ]
Levin, CS [1 ]
Hoffman, EJ [1 ]
机构
[1] UNIV CALIF LOS ANGELES,SCH MED,DIV NUCL MED & BIOPHYS,DEPT MOL & MED PHARMACOL,LOS ANGELES,CA 90095
基金
美国国家卫生研究院;
关键词
D O I
10.1109/23.596995
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A 256-element mercuric iodide (HgI2) detector array has been developed which is intended for use as an intraoperative gamma camera (IOGC). The camera is specifically designed for use in imaging gamma-emitting radiopharmaceuticals (such as 99m-Tc labeled Sestamibi) incorporated into brain tumors in the intraoperative surgical environment. The system is intended to improve the success of tumor removal surgeries by allowing more complete removal of subclinical tumor cells without removal of excessive normal tissue. The use of HgI2 detector arrays in this application facilitates construction of an imaging head that is very compact and has a high SNR. The detector is configured as a cross-grid array. Pixel dimensions are 1.25 mm squares separated by 0.25 mm. The overall dimension of the detector is 23.75 mm on a side. The detector thickness is 1 mm which corresponds to over 60% stopping at 140 keV. The array has good uniformity with average energy resolution of 5.2 +/- 2.9 % FWHM at 140 keV (best resolution was 1.9 % FWHM). Response uniformity (+/- sigma) was 7.9 %. A study utilizing realistic tumor phantoms (uptake ratio varied from 2:1 to 100:1) in background (1 mCi/l) was conducted. SNR's for the reasonably achievable uptake ratio of 50:1 were 5.61 sigma with 1 cm of background depth (''normal tissue'') and 2.74 sigma with 4 cm of background for a 6.3 mu l tumor phantom (similar to 270 nCi at the time of the measurement).
引用
收藏
页码:1242 / 1248
页数:7
相关论文
共 16 条
[1]   A GAMMA-DETECTING PROBE FOR RADIOIMMUNE DETECTION OF CEA-PRODUCING TUMORS - SUCCESSFUL EXPERIMENTAL USE AND CLINICAL CASE-REPORT [J].
AITKEN, DR ;
HINKLE, GH ;
THURSTON, MO ;
TUTTLE, SE ;
MARTIN, DT ;
OLSEN, J ;
HAAGENSEN, DE ;
HOUCHENS, D ;
MARTIN, EW .
DISEASES OF THE COLON & RECTUM, 1984, 27 (05) :279-282
[2]   COMPARISON OF INVIVO SCINTILLATION PROBES AND GAMMA CAMERAS FOR DETECTION OF SMALL, DEEP TUMORS [J].
BARBER, HB ;
BARRETT, HH ;
WOOLFENDEN, JM ;
MYERS, KJ ;
HICKERNELL, TS .
PHYSICS IN MEDICINE AND BIOLOGY, 1989, 34 (06) :727-739
[3]   CORTICAL MAPPING FOR DEFINING THE LIMITS OF TUMOR RESECTION [J].
BLACK, PM ;
RONNER, SF .
NEUROSURGERY, 1987, 20 (06) :914-919
[4]  
MACDONALD LR, 1995, P SOC PHOTO-OPT INS, V2551, P92, DOI 10.1117/12.218645
[5]  
MAUBLANT JC, 1993, J NUCL MED, V34, P1949
[6]  
NAZARRO JM, 1990, J NEUROSURG, V73, P331
[7]  
ODWYER PJ, 1986, ARCH SURG-CHICAGO, V121, P1391
[8]  
OTUAMA LA, 1993, J NUCL MED, V34, P1045
[9]   TUMOR UPTAKE OF (99M)TC MIBI AND (201)TL BY A 9L GLIOSARCOMA BRAIN-TUMOR MODEL IN RATS [J].
PACKARD, AB ;
KRONAUGE, JF ;
LIMPAAMARA, N ;
LAMPSON, L ;
OTUAMA, LA ;
JONES, AG .
NUCLEAR MEDICINE AND BIOLOGY, 1993, 20 (06) :773-776
[10]   TC-99M MIBI BRAIN SPECT IN THE DIAGNOSIS OF RECURRENT GLIOMA [J].
PARK, CH ;
KIM, SM ;
ZHANG, JJ ;
INTENZO, CM ;
MCEWAN, JR .
CLINICAL NUCLEAR MEDICINE, 1994, 19 (01) :57-58