A review of the main factors influencing the FT-IR-PLS abilities exemplified with petrochemical qualimetric applications

被引:16
作者
Andrade, JM
Garcia, MV
LopezMahia, P
Prada, D
机构
关键词
infrared; PLS; qualimetrics; FT-IR; review;
D O I
10.1016/S0039-9140(97)00034-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Quality control usually involves monitoring several variables directly related with industrial necessities using univariate tests. One powerful alternative is to link multivariate analytical techniques and multivariate chemometrics. In this way, Fourier Transform Infrared spectroscopy and Partial Least Squares regression are used to discuss and review several advantages and drawbacks encountered in using such combination in industrial facilities. Typical drawbacks are selection of data pretreatment, errors in reference methods, selection of calibration and Validation sets and model-aging. This review is exemplified with petrochemical applications although other fields are also considered (mainly when dealing with data pretreatment). (C) 1997 Elsevier Science B.V.
引用
收藏
页码:2167 / 2184
页数:18
相关论文
共 123 条
[1]   ON THE EFFECT OF CALIBRATION AND THE ACCURACY OF NIR SPECTROSCOPY WITH HIGH-LEVELS OF NOISE IN THE REFERENCE VALUES [J].
AASTVEIT, AH ;
MARUM, P .
APPLIED SPECTROSCOPY, 1991, 45 (01) :109-115
[2]   COMPRESSION OF NTH-ORDER DATA ARRAYS BY B-SPLINES .1. THEORY [J].
ALSBERG, BK ;
KVALHEIM, OM .
JOURNAL OF CHEMOMETRICS, 1993, 7 (01) :61-73
[3]   COMPRESSION OF NTH-ORDER DATA ARRAYS BY B-SPLINES .2. APPLICATION TO 2ND-ORDER FT-IR SPECTRA [J].
ALSBERG, BK ;
NODLAND, E ;
KVALHEIM, OM .
JOURNAL OF CHEMOMETRICS, 1994, 8 (02) :127-145
[4]   COSTS, LABORATORY SAFETY, PRODUCTIVITY AND FASTER RESEARCH OCTANE NUMBER AND MOTOR OCTANE NUMBER DETERMINATIONS IN INDUSTRIAL CHEMISTRY LABORATORIES [J].
ANDRADE, JM ;
MUNIATEGUI, S ;
LOPEZ, P ;
PRADA, D .
ANALYST, 1995, 120 (02) :249-253
[5]  
ANDRADE JM, 1992, QUIM ANAL, V11, P181
[6]  
[Anonymous], 1995, ANN BOOK ASTM STAND, DOI DOI 10.1520/2002C
[7]   QUANTITATIVE GAS-ANALYSIS WITH FT-IR - METHOD FOR CO CALIBRATION USING PARTIAL LEAST-SQUARES WITH LINEARIZED DATA [J].
BAK, J ;
LARSEN, A .
APPLIED SPECTROSCOPY, 1995, 49 (04) :437-443
[8]   SMOOTHING AND DIFFERENTIATION BY AN ADAPTIVE-DEGREE POLYNOMIAL FILTER [J].
BARAK, P .
ANALYTICAL CHEMISTRY, 1995, 67 (17) :2758-2762
[9]   STANDARD NORMAL VARIATE TRANSFORMATION AND DE-TRENDING OF NEAR-INFRARED DIFFUSE REFLECTANCE SPECTRA [J].
BARNES, RJ ;
DHANOA, MS ;
LISTER, SJ .
APPLIED SPECTROSCOPY, 1989, 43 (05) :772-777
[10]  
Benedetto J.J., 1994, Wavelets: Mathematics and Applications