High-accuracy standard specimens for the line-focus-beam ultrasonic material characterization system

被引:38
作者
Kushibiki, J [1 ]
Arakawa, M [1 ]
Okabe, R [1 ]
机构
[1] Tohoku Univ, Dept Elect Engn, Sendai, Miyagi 9808579, Japan
基金
日本学术振兴会;
关键词
D O I
10.1109/TUFFC.2002.1009343
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
We prepared standard specimens for the line-focus-beam ultrasonic material characterization system to obtain absolute values of the propagation characteristics (phase velocity and attenuation) of leaky surface acoustic waves (LSAWs). The characterization system is very useful for evaluating and analyzing specimen surfaces. The calibration accuracy of these acoustic parameters depends on the accuracy of acoustical physical constants (elastic constants, piezoelectric constants, dielectric constants, and density) determined for standard specimens. In this paper, we developed substrates of nonpiezoelectric single crystals (viz., gadolinium gallium garnet [GGG], Si, and Ge) and an isotropic solid (synthetic silica [SiO2] glass) as standard specimens. These specimens can cover the phase velocity range of 2600 to 5100 m/s for Rayleigh-type LSAWs. To determine the elastic constants with high accuracy, we measured velocities by the complex-mode measurement method and corrected diffraction effects. Measurements of bulk acoustic properties (bulk wave velocity and density) were conducted around 23degreesC, and bulk wave velocities were obtained with an accuracy of within +/-0.004%. We clearly detected differences in acoustic properties by comparing the obtained results with the previously published values; the differences were considered to be due to differences of the specimens used. We also detected differences in acoustic properties among four SiO2 substrates produced by different manufacturers.
引用
收藏
页码:827 / 835
页数:9
相关论文
共 56 条
[1]   COEFFICIENT OF LINEAR EXPANSION OF SILICON AND GERMANIUM BY DOUBLE CRYSTAL X-RAY SPECTROMETER [J].
BHALLA, AS ;
WHITE, EW .
PHYSICA STATUS SOLIDI A-APPLIED RESEARCH, 1971, 5 (01) :K51-&
[2]  
BIR GL, 1963, SOV PHYS-SOL STATE, V4, P1925
[3]   PROCEDURE FOR HIGH PRECISION DENSITY DETERMINATIONS BY HYDROSTATIC WEIGHING [J].
BOWMAN, HA ;
SCHOONOV.RM .
JOURNAL OF RESEARCH OF THE NATIONAL BUREAU OF STANDARDS SECTION C-ENGINEERING AND INSTRUMENTATION, 1967, C 71 (03) :179-+
[4]   ELECTRONIC EFFECT IN ELASTIC CONSTANTS OF GERMANIUM [J].
BRUNER, LJ ;
KEYES, RW .
PHYSICAL REVIEW LETTERS, 1961, 7 (02) :55-&
[5]   ACOUSTIC PROPERTIES OF PROTON-EXCHANGED LINBO3 STUDIED USING THE ACOUSTIC MICROSCOPY V(Z) TECHNIQUE [J].
BURNETT, PJ ;
BRIGGS, GAD ;
ALSHUKRI, SM ;
DUFFY, JF ;
DELARUE, RM .
JOURNAL OF APPLIED PHYSICS, 1986, 60 (07) :2517-2522
[6]   ZNO FILMS FOR SURFACE ACOUSTOOPTIC DEVICES ON NONPIEZOELECTRIC SUBSTRATES [J].
CHUBACHI, N .
PROCEEDINGS OF THE IEEE, 1976, 64 (05) :772-774
[7]   OPTICAL STUDY OF ULTRASONIC DIFFRACTION AND FOCUSING IN ANISOTROPIC MEDIA [J].
COHEN, MG .
JOURNAL OF APPLIED PHYSICS, 1967, 38 (10) :3821-&
[8]   EFFECT OF DOPING ON ELASTIC CONSTANTS OF SILICON [J].
CSAVINSZKY, P ;
EINSPRUCH, NG .
PHYSICAL REVIEW, 1963, 132 (06) :2434-&
[9]   EQUATION FOR THE DETERMINATION OF THE DENSITY OF MOIST AIR (1981/91) [J].
DAVIS, RS .
METROLOGIA, 1992, 29 (01) :67-70
[10]   ELECTRONIC EFFECT IN THE ELASTIC CONSTANT C' OF SILICON [J].
EINSPRUCH, NG ;
CSAVINSZKY, P .
APPLIED PHYSICS LETTERS, 1963, 2 (01) :1-3