Comparative study of the use of high-performance liquid chromatography and capillary electrophoresis for determination of phenolic compounds in water samples

被引:26
作者
Martinez, D [1 ]
Pocurull, E [1 ]
Marce, RM [1 ]
Borrull, F [1 ]
Calull, M [1 ]
机构
[1] UNIV ROVIRA & VIRGILI,DEPT QUIM,E-43005 TARRAGONA,SPAIN
关键词
column liquid chromatography; capillary electrophoresis; phenolic compounds; water samples;
D O I
10.1007/BF02292977
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A comparative study of high-performance liquid chromatography (HPLC) and capillary zone electrophoresis (CZE) for determination of eleven EPA priority phenols in water samples is discussed. The repeatability, linearity and detection limits of both methods are compared. A solid-phase extraction method using a highly cross-linked styrene-divinylbenzene copolymer sorbent is used for the off-line preconcentration process in order to determine these compounds in water at low levels. Both methods are used to determine phenolic compounds in Ebro river and industrial waste water. Identification was achieved by comparison of the UV spectra corresponding to the different peaks, acquired with a diode-array detector, with those in a spectral library.
引用
收藏
页码:619 / 624
页数:6
相关论文
共 24 条
[1]   DETERMINATION OF PHENOLS BY HPLC DOWN TO PPT LEVELS [J].
BALDWIN, DA ;
DEBOWSKI, JK .
CHROMATOGRAPHIA, 1988, 26 :186-190
[2]   ONLINE SAMPLE TREATMENT FOR OR VIA COLUMN LIQUID-CHROMATOGRAPHY [J].
BRINKMAN, UAT .
JOURNAL OF CHROMATOGRAPHY A, 1994, 665 (02) :217-231
[3]   CAPILLARY ZONE ELECTROPHORESIS OF 11 PRIORITY PHENOLS WITH INDIRECT FLUORESCENCE DETECTION [J].
CHAO, YC ;
WHANG, CW .
JOURNAL OF CHROMATOGRAPHY A, 1994, 663 (02) :229-237
[4]   CAPILLARY ZONE ELECTROPHORESIS OF 11 PRIORITY PHENOLS WITH AMPEROMETRIC DETECTION [J].
CHEN, IC ;
WHANG, CW .
JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 1994, 41 (04) :419-424
[5]   SOLID-PHASE EXTRACTION IN MULTI-RESIDUE PESTICIDE ANALYSIS OF WATER [J].
FONT, G ;
MANES, J ;
MOLTO, JC ;
PICO, Y .
JOURNAL OF CHROMATOGRAPHY, 1993, 642 (1-2) :135-161
[6]   DETERMINATION OF PHENOLS IN SEA-WATER BY LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION AFTER ENRICHMENT BY USING SOLID-PHASE EXTRACTION CARTRIDGES AND DISKS [J].
GALCERAN, MT ;
JAUREGUI, O .
ANALYTICA CHIMICA ACTA, 1995, 304 (01) :75-84
[7]  
HEDGES JI, 1982, ANAL CHEM, V54, P174, DOI 10.1021/ac00239a007
[9]   THE USE OF LIQUID SOLID EXTRACTION, CAPILLARY COLUMN GC/MS FOR THE ANALYSIS OF CHLORINATED ACIDS AND PHENOLS IN DRINKING-WATER [J].
INFANTE, R ;
GUTIERREZ, C ;
PEREZ, C .
WATER SCIENCE AND TECHNOLOGY, 1992, 26 (9-11) :2583-2586
[10]   MICELLAR ELECTROKINETIC CAPILLARY CHROMATOGRAPHY OF ACIDIC SOLUTES - MIGRATION BEHAVIOR AND OPTIMIZATION STRATEGIES [J].
KHALEDI, MG ;
SMITH, SC ;
STRASTERS, JK .
ANALYTICAL CHEMISTRY, 1991, 63 (17) :1820-1830