The reporting, classification and grading of quality failures in the medical laboratory

被引:32
作者
O'Kane, Maurice
机构
[1] Clinical Chemistry Laboratory, Altnagelvin Hospital, Londonderry, N Ireland
关键词
Errors in laboratory medicine; Quality failures; Classification and grading system; Adverse events; Patient safety; ERRORS; FREQUENCY; BLUNDERS; MISTAKES; SAFETY; SYSTEM; CARE;
D O I
10.1016/j.cca.2009.03.023
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Laboratory errors have a reported frequency of 0.012 to 0.6% of all test results and given the central role of the laboratory in diagnosis, may have a major adverse impact on patient care. Laboratories have been at the forefront of efforts to enhance patient safety through a range of improvements such as increased automation of manual processes and analytical quality control programmes. It is important that all laboratories have active systems in place to identify and monitor quality failures. This will be facilitated by a systems based approach to error which seeks to identify and correct weaknesses in policies/procedures rather than to apportion blame. Quality failures may be classified by cause [i.e.. step in the testing pathway where the problem occurred] and graded by severity on a 5 point scale. The severity grading score measures both the Actual impact ['A' score] on patient outcome and the Potential impact ['P' score] i.e., the worst case possible outcome that might have resulted. 'A' scores tend to be skewed towards low adverse patient impact while 'P' scores are skewed towards high adverse impact. This confirms the need for ongoing vigilance by laboratories. This classification/grading system is easy to implement and represents a valuable additional tool for monitoring performance. (c) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:28 / 31
页数:4
相关论文
共 21 条
[1]  
[Anonymous], ERR IS HUMAN BUILDIN
[2]  
Blumenthal D, 1997, CLIN CHEM, V43, P1305
[3]  
Bonini P, 2002, CLIN CHEM, V48, P691
[4]   Accidental deaths, saved lives, and improved quality [J].
Brennan, TA ;
Gawande, A ;
Thomas, E ;
Studdert, D .
NEW ENGLAND JOURNAL OF MEDICINE, 2005, 353 (13) :1405-1409
[5]   Errors in a stat laboratory: Types and frequencies 10 years later [J].
Carraro, Paolo ;
Plebani, Mario .
CLINICAL CHEMISTRY, 2007, 53 (07) :1338-1342
[6]   Institutional resilience in healthcare systems [J].
Carthey, J ;
de Leval, MR ;
Reason, JT .
QUALITY IN HEALTH CARE, 2001, 10 (01) :29-32
[7]  
Goldschmidt HMJ., 1995, Klin Biochem Metab, V3, P131
[8]  
Hofgärtner WT, 1999, AM J CLIN PATHOL, V112, P14
[9]  
Howanitz PJ, 2005, ARCH PATHOL LAB MED, V129, P1252
[10]  
*INT ORG STAND, 2005, 22367 ISOPDTS, P9