Validation of a standardized portable fluorescence method for determining trace beryllium in workplace air and wipe samples

被引:27
作者
Agrawal, Anoop
Cronin, John
Tonazzi, Juan
McCleskey, T. Mark
Ehler, Deborah S.
Minogue, Edel M.
Whitney, Gary
Brink, Christopher
Burrell, Anthony K.
Warner, Benjamin
Goldcamp, Michael J.
Schlecht, Paul C.
Sonthalia, Prerna
Ashley, Kevin
机构
[1] Berylliant Inc, Tucson, AZ 85712 USA
[2] Los Alamos Natl Lab, Los Alamos, NM 87545 USA
[3] Wilmington Coll, Dept Chem, Wilmington, OH 45177 USA
[4] NIOSH, US Dept HHS, Ctr Dis Control & Prevent, Cincinnati, OH 45226 USA
来源
JOURNAL OF ENVIRONMENTAL MONITORING | 2006年 / 8卷 / 06期
关键词
D O I
10.1039/b601524g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Beryllium is widely used in industry for its unique properties; however, occupational exposure to beryllium particles can cause potentially fatal disease. Consequently, exposure limits for beryllium particles in air and action levels on surfaces have been established to reduce exposure risks for workers. Field-portable monitoring methods for beryllium are desired in order to facilitate on-site measurement of beryllium in the workplace, so that immediate action can be taken to protect human health. In this work, a standardized, portable fluorescence method for the determination of trace beryllium in workplace samples, i.e., air filters and dust wipes, was validated through intra- and inter-laboratory testing. The procedure entails extraction of beryllium in 1% ammonium bifluoride (NH4HF2, aqueous), followed by fluorescence measurement of the complex formed between beryllium ion and hydroxybenzoquinoline sulfonate (HBQS). The method detection limit was estimated to be less than 0.02 mu g Be per air filter or wipe sample, with a dynamic range up to greater than 10 mg. The overall method accuracy was shown to satisfy the accuracy criterion (A <= +/- 25%) for analytical methods promulgated by the US National Institute for Occupational Safety and Health (NIOSH). Interferences from numerous metals tested ( in > 400-fold excess concentration compared to that of beryllium) were negligible or minimal. The procedure was shown to be effective for the dissolution and quantitative detection of beryllium extracted from refractory beryllium oxide particles. An American Society for Testing and Materials (ASTM) International voluntary consensus standard based on the methodology has recently been published.
引用
收藏
页码:619 / 624
页数:6
相关论文
共 17 条
[1]  
*ASTM, 2004, D7035 ASTM
[2]  
*ASTM INT, 1999, E691 ASTM
[3]  
*ASTM INT, D7202 ASTM
[4]   DETERMINATION OF BERYLLIUM IN WATER BY ION-EXCHANGE SPECTROFLUORIMETRY [J].
CAPITAN, F ;
MANZANO, E ;
NAVALON, A ;
VILCHEZ, JL ;
CAPITANVALLVEY, LF .
ANALYST, 1989, 114 (08) :969-973
[5]  
KENNEDY ER, 1995, DHHS NIOSH PUBL
[6]  
Kolanz M E, 2001, Appl Occup Environ Hyg, V16, P559, DOI 10.1080/104732201750169651
[7]   A novel fluorescence reagent, 10-hydroxybenzo[h]quinoline-7-sulfonate, for selective determination of beryllium(II) ion at pg cm-3 levels [J].
Matsumiya, H ;
Hoshino, H ;
Yotsuyanagi, T .
ANALYST, 2001, 126 (11) :2082-2086
[8]   CHROMOTROPIC-ACID AS FLUOROGENIC REAGENT .1. FLUOROMETRIC-DETERMINATION OF BERYLLIUM [J].
PAL, BK ;
BAKSI, K .
MIKROCHIMICA ACTA, 1992, 108 (3-6) :275-283
[9]  
RAINS TC, 1974, 73439 NBSIR
[10]   OPTICAL SENSOR FOR BERYLLIUM BASED ON IMMOBILIZED MORIN FLUORESCENCE [J].
SAARI, LA ;
SEITZ, WR .
ANALYST, 1984, 109 (05) :655-657