Three-dimensional gadolinium-enhanced coronary magnetic resonance angiography: Initial experience

被引:33
作者
Zheng, J [1 ]
Li, DB [1 ]
Bae, KT [1 ]
Haacke, EM [1 ]
机构
[1] Washington Univ, Sch Med, Mallinckrodt Inst Radiol, St Louis, MO 63130 USA
关键词
contrast agents; coronary artery; MR angiography;
D O I
10.3109/10976649909080831
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We present our initial experience on first-pass gadolinium-enhanced corollary artery magnetic resonance angiography (MRA). Three-dimensional segmented gradient-echo sequences were developed to image coronary arteries within a single breathhold during the injection of a double-dose contrast agent. Comparisons were made between a short TR of 2.7-msec (n = 5) and a long TR of 5.0-msec (n = 3) sequences in terms of the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). An in-plane resolution of roughly I X I mm(2) was achieved. Dramatic vascular signal enhancement by a factor of 3-5 was obtained in volunteers following the contrast agent injection, allowing for clear visualization of proximal corollary arteries. The longer TR scans generally performed better in terms of SNR and CNR improvement (approximately 50%) but allowed for less covet-age. These preliminary results suggest that gadolinium-enhanced MRA is a useful tool to study proximal coronary arteries with breathhold, but for a larger coverage, a multiple close approach may be necessary.
引用
收藏
页码:33 / 41
页数:9
相关论文
共 31 条
  • [1] DYNAMIC CONTRAST-ENHANCED SUBTRACTION MR-ANGIOGRAPHY OF THE LOWER-EXTREMITIES - INITIAL EVALUATION WITH A MULTISECTION 2-DIMENSIONAL TIME-OF-FLIGHT SEQUENCE
    ADAMIS, MK
    LI, W
    WIELOPOLSKI, PA
    KIM, D
    SAX, EJ
    KENT, KC
    EDELMAN, RR
    [J]. RADIOLOGY, 1995, 196 (03) : 689 - 695
  • [2] BAE KT, 1998, P INT SOC MAGN RES M, P764
  • [3] CORONARY-ARTERY IMAGING IN MULTIPLE 1-SEC BREATH HOLDS
    DOYLE, M
    SCHEIDEGGER, MB
    DEGRAAF, RG
    VERMEULEN, J
    POHOST, GM
    [J]. MAGNETIC RESONANCE IMAGING, 1993, 11 (01) : 3 - 6
  • [4] 2-DIMENSIONAL CORONARY MR-ANGIOGRAPHY - ANALYSIS OF INITIAL CLINICAL-RESULTS
    DUERINCKX, AJ
    URMAN, MK
    [J]. RADIOLOGY, 1994, 193 (03) : 731 - 738
  • [5] Breath-hold single-dose gadolinium-enhanced three-dimensional MR aortography: Usefulness of a timing examination and MR power injector
    Earls, JP
    Rofsky, NM
    DeCorato, DR
    Krinsky, GA
    Weinreb, JC
    [J]. RADIOLOGY, 1996, 201 (03) : 705 - 710
  • [6] CORONARY-ARTERIES - BREATH-HOLD MR ANGIOGRAPHY
    EDELMAN, RR
    MANNING, WJ
    BURSTEIN, D
    PAULIN, S
    [J]. RADIOLOGY, 1991, 181 (03) : 641 - 643
  • [7] GOLDFARB JW, 1998, RADIOLOGY, V187, P719
  • [8] Evaluation of the aortoiliac and renal arteries: Comparison of breath-hold, contrast-enhanced, three-dimensional MR angiography with conventional catheter angiography
    Hany, TF
    Debatin, JF
    Leung, DA
    Pfammatter, T
    [J]. RADIOLOGY, 1997, 204 (02) : 357 - 362
  • [9] Optimization of contrast timing for breath-hold three-dimensional MR angiography
    Hany, TF
    McKinnon, GC
    Leung, DA
    Pfammatter, T
    Debatin, JF
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (03): : 551 - 556
  • [10] Pulmonary perfusion and angiography: Evaluation with breath-hold enhanced three-dimensional fast imaging steady-state precession MR imaging with short TR and TE
    Hatabu, H
    Gaa, J
    Kim, D
    Li, W
    Prasad, PV
    Edelman, RR
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (03) : 653 - 655