Use of a segmented array charge coupled device detector for continuum source atomic absorption spectrometry with graphite furnace atomization

被引:25
作者
Harnly, JM
Smith, CMM
Wichems, DN
Ivaldi, JC
Lundberg, PL
Radziuk, B
机构
[1] PERKIN ELMER CORP,NORWALK,CT 06859
[2] BODENSEEWERK PERKIN ELMER & CO GMBH,D-88647 UBERLINGEN,GERMANY
关键词
segmented array; charge coupled device; continuum source; atomic absorption spectrometry; graphite furnace atomisation;
D O I
10.1039/a608440k
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学]; 081704 [应用化学];
摘要
A commercially available echelle spectrometer with a segmented array charge coupled detector (SCD) was used with a xenon are lamp and graphite furnace atomizer for continuum source atomic absorption spectrometry (CS-AAS), Approximately 67% of the spectral wavelengths corresponding to the resonance transitions used for routine AAS determinations were available on the SCD, As many as eight elements were determined simultaneously with a read frequency of 50 Hz for each array, The high luminosity of the echelle and the high quantum efficiency SCD provided photoelectron levels that ranged from equivalent to 7 times higher than those previously measured by CS-AAS using a linear photodiode array (LPDA) detector, The low read noise of the SCD resulted in the absorbance measurements being limited by the photon shot noise of the continuum source, Detection limits were obtained that ranged from equivalent to a factor of 3 better than those previously obtained for CS-AAS and from a factor of 2 worse to a factor of 10 better than those for conventional, line source AAS, Sensitivities, as determined by intrinsic mass (mass necessary for an absorbance of 0.0044 pm s), were similar to those measured previously with an LPDA, The high resolution of the echelle allowed detailed inspection of the spectra surrounding the wavelength of the elements determined, Data were displayed using contour absorbance plots, Molecular peaks were observed within the spectral window of the sub-arrays fbr As (193.7 nm) and Se (196.0 nm), These peaks were spectrally and temporally resolved from the analyte peaks and disappeared in the presence of a Pd chemical modifier, A low sensitivity Pd line was identified that was 15 pm from the Se line, The Pd and Se peaks were resolved using a spectral bandwidth of 3 pm per pixel.
引用
收藏
页码:617 / 627
页数:11
相关论文
共 14 条
[1]
SOLID-STATE DETECTOR FOR ICP-OES [J].
BARNARD, TW ;
CROCKETT, MI ;
IVALDI, JC ;
LUNDBERG, PL ;
YATES, DA ;
LEVINE, PA ;
SAUER, DJ .
ANALYTICAL CHEMISTRY, 1993, 65 (09) :1231-1239
[2]
DESIGN AND EVALUATION OF AN ECHELLE GRATING OPTICAL-SYSTEM FOR ICP-OES [J].
BARNARD, TW ;
CROCKETT, MI ;
IVALDI, JC ;
LUNDBERG, PL .
ANALYTICAL CHEMISTRY, 1993, 65 (09) :1225-1230
[3]
THE EFFECT OF SPECTRAL BANDPASS ON SIGNAL-TO-NOISE RATIOS FOR CONTINUUM SOURCE ATOMIC-ABSORPTION SPECTROMETRY WITH A LINEAR PHOTODIODE-ARRAY DETECTOR [J].
HARNLY, JM .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1993, 48 (6-7) :909-924
[4]
Extended calibration ranges for continuum source atomic absorption spectrometry with array detection [J].
Harnly, JM ;
Smith, CMM ;
Radziuk, B .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1996, 51 (9-10) :1055-1079
[5]
GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY USING A LINEAR PHOTODIODE-ARRAY AND A CONTINUUM SOURCE [J].
HARNLY, JM .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (02) :317-324
[6]
HEITMANN U, 1996, IN PRESS FRESENIUS J
[7]
MASSMANN H, 1982, TALANTA, V29, P1051, DOI 10.1016/0039-9140(82)80248-8
[8]
MORTARA L, 1981, P SOC PHOTO-OPT INST, V290, P28
[9]
*NAT I STAND TECHN, 488 NAT I STAND TECH
[10]
EFFECT OF THE SOURCE ABSORBER WIDTH RATIO ON THE SIGNAL-TO-NOISE RATIO OF DISPERSIVE ABSORPTION SPECTROMETRY [J].
OHAVER, TC .
ANALYTICAL CHEMISTRY, 1991, 63 (02) :164-169