A rapid biosensor for viable B-anthracis spores

被引:39
作者
Baeumner, AJ [1 ]
Leonard, B
McElwee, J
Montagna, RA
机构
[1] Cornell Univ, Dept Biol & Environm Engn, Ithaca, NY 14853 USA
[2] Innovat Biotechnol Int Inc, Grand Isl, NY 14072 USA
关键词
biosensor; B; anthracis; RNA; detection; spore; viable; biosecurity; protective antigen;
D O I
10.1007/s00216-004-2726-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple membrane-strip-based biosensor assay has been combined with a nucleic acid sequence-based amplification (NASBA) reaction for rapid (4 h) detection of a small number (ten) of viable B. anthracis spores. The biosensor is based on identification of a unique mRNA sequence from one of the anthrax toxin genes, the protective antigen (pag), encoded on the toxin plasmid, pXO1, and thus provides high specificity toward B. anthracis. Previously, the anthrax toxins activator (atxA) mRNA had been used in our laboratory for the development of a biosensor for the detection of a single B. anthracis spore within 12 h. Changing the target sequence to the pag mRNA provided the ability to shorten the overall assay time significantly. The vaccine strain of B. anthracis (Sterne strain) was used in all experiments. A 500-muL sample containing as few as ten spores was mixed with 500 muL growth medium and incubated for 30 min for spore germination and mRNA production. Thus, only spores that are viable were detected. Subsequently, RNA was extracted from lysed cells, selectively amplified using NASBA, and rapidly identified by the biosensor. While the biosensor assay requires only 15 min assay time, the overall process takes 4 h for detection of ten viable B. anthracis spores, and is shortened significantly if more spores are present. The biosensor is based on an oligonucleotide sandwich-hybridization assay format. It uses a membrane flow-through system with an immobilized DNA probe that hybridizes with the target sequence. Signal amplification is provided when the target sequence hybridizes to a second DNA probe that has been coupled to liposomes encapsulating the dye sulforhodamine B. The amount of liposomes captured in the detection zone can be read visually or quantified with a hand-held reflectometer. The biosensor can detect as little as 1 fmol target mRNA (1 nmol L-1). Specificity analysis revealed no cross-reactivity with 11 organisms tested, among them closely related species such as B. cereus, B. megaterium, B. subtilis, B. thuringiensis, Lactococcus lactis, Lactobacillus plantarum, and Chlostridium butyricum. Also, no false positive signals were obtained from nonviable spores. We suggest that this inexpensive biosensor is a viable option for rapid, on-site analysis providing highly specific data on the presence of viable B. anthracis spores.
引用
收藏
页码:15 / 23
页数:9
相关论文
共 47 条
[1]   Detection of anthrax simulants with microcalorimetric spectroscopy:: Bacillus subtilis and Bacillus cereus spores [J].
Arakawa, ET ;
Lavrik, NV ;
Datskos, PG .
APPLIED OPTICS, 2003, 42 (10) :1757-1762
[2]   RNA biosensor for the rapid detection of viable Escherichia coli in drinking water [J].
Baeumner, AJ ;
Cohen, RN ;
Miksic, V ;
Min, JH .
BIOSENSORS & BIOELECTRONICS, 2003, 18 (04) :405-413
[3]   Biosensor for Dengue virus detection: Sensitive, rapid, and serotype specific [J].
Baeumner, AJ ;
Schlesinger, NA ;
Slutzki, NS ;
Romano, J ;
Lee, EM ;
Montagna, RA .
ANALYTICAL CHEMISTRY, 2002, 74 (06) :1442-1448
[4]   A minisonicator to rapidly disrupt bacterial spores for DNA analysis [J].
Belgrader, P ;
Hansford, D ;
Kovacs, GTA ;
Venkateswaran, K ;
Mariella, R ;
Milanovich, F ;
Nasarabadi, S ;
Okuzumi, M ;
Pourahmadi, F ;
Northrup, MA .
ANALYTICAL CHEMISTRY, 1999, 71 (19) :4232-4236
[5]   Detection of Bacillus anthracis DNA by LightCycler PCR [J].
Bell, CA ;
Uhl, JR ;
Hadfield, TL ;
David, JC ;
Meyer, RF ;
Smith, TF ;
Cockerill, FR .
JOURNAL OF CLINICAL MICROBIOLOGY, 2002, 40 (08) :2897-2902
[6]  
BEYER W, 1995, MICROBIOL RES, V150, P179, DOI 10.1016/S0944-5013(11)80054-6
[7]   RAPID AND SIMPLE METHOD FOR PURIFICATION OF NUCLEIC-ACIDS [J].
BOOM, R ;
SOL, CJA ;
SALIMANS, MMM ;
JANSEN, CL ;
WERTHEIMVANDILLEN, PME ;
VANDERNOORDAA, J .
JOURNAL OF CLINICAL MICROBIOLOGY, 1990, 28 (03) :495-503
[8]   DETECTION OF SPORES OF BACILLUS-ANTHRACIS USING THE POLYMERASE CHAIN-REACTION [J].
CARL, M ;
HAWKINS, R ;
COULSON, N ;
LOWE, J ;
ROBERTSON, DL ;
NELSON, WM ;
TITBALL, RW ;
WOODY, JN .
JOURNAL OF INFECTIOUS DISEASES, 1992, 165 (06) :1145-1148
[9]   A simple and sensitive detection system for Bacillus anthracis in meat and tissue [J].
Cheun, HI ;
Makino, SI ;
Wataral, M ;
Shirahata, T ;
Uchida, I ;
Takeshi, K .
JOURNAL OF APPLIED MICROBIOLOGY, 2001, 91 (03) :421-426
[10]   Bacillus anthracis virulence in guinea pigs vaccinated with anthrax vaccine adsorbed is linked to plasmid quantities and clonality [J].
Coker, PR ;
Smith, KL ;
Fellows, PF ;
Rybachuck, G ;
Kousoulas, KG ;
Hugh-Jones, ME .
JOURNAL OF CLINICAL MICROBIOLOGY, 2003, 41 (03) :1212-1218