Hydrodynamic voltammetry with channel microband electrodes: The simulation of voltammetric waveshapes

被引:33
作者
Bidwell, MJ [1 ]
Alden, JA [1 ]
Compton, RG [1 ]
机构
[1] UNIV OXFORD,PHYS & THEORET CHEM LAB,OXFORD OX1 3QZ,ENGLAND
来源
JOURNAL OF ELECTROANALYTICAL CHEMISTRY | 1996年 / 417卷 / 1-2期
关键词
channel microband electrodes; hydrodynamic voltammetry; simulation; strongly implicit procedure; multigrid method MGD1; current-voltage waveshapes;
D O I
10.1016/S0022-0728(96)04739-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The strongly implicit procedure and the multigrid method MGD1 are used to simulate the steady-state current-voltage response of channel electrodes, including under conditions where diffusional effects in the direction of flow are significant. Reversible, quasi-reversible and irreversible heterogeneous kinetics are all considered.
引用
收藏
页码:119 / 128
页数:10
相关论文
共 32 条