Fracture strengths of provisional restorations reinforced with plasma-treated woven polyethylene fiber

被引:56
作者
Samadzadeh, A [1 ]
Kugel, G [1 ]
Hurley, E [1 ]
Aboushala, P [1 ]
机构
[1] TUFTS UNIV,SCH DENT MED,DEPT RESTORAT DENT,BOSTON,MA 02111
关键词
D O I
10.1016/S0022-3913(97)70058-1
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Fracture strength of interim fixed partial prosthesis is of great concern, especially in long-span restorations or areas of heavy occlusal stress. Purpose. Effects of a plasma-treated woven polyethylene fiber (Ribbond) on the fracture strength of polymethyl methacrylate (Coldpac) and a resin-based two-phase curing provisional restorative material (Provipont DC) were evaluated. Material and methods. A polpvinyl siloxane template was used to fabricate three-unit posterior provisional prostheses on a stainless steel die with two abutments 22 mm apart. The reinforced groups were fabricated by affixing 3 mm wide pieces of fiber treated with methyl methacrylate monomer or polyisocyanate (activator part of Provipont DC) on the occlusal surfaces of abutments. The interim materials were mixed, according to the manufacturers' specifications, and placed in the template. The template was pressed on the die and held secure until complete setting of the material occurred by light curing (Provipont DC) or autopolymerization (PMMA). The specimens were divided into 4 groups of 10 each (A, reinforced Provipont DC; B, unreinforced Provipont DC; C, reinforced PMMA; and D, unreinforced PMMA). A central compressive load force was exerted on the specimen to determine the fracture load of the restorations. Results. The data revealed mean fracture loads of A, 65.59 +/- 11.27 kg; B, 46.59 +/- 14.84 kg; C, 53.46 +/- 7.76 kg; and D, 49.86 +/- 14.44 kg. Conclusion. Plasma-treated polyethylene reinforced PMMA restorations showed no significant increase in fracture loads when compared with unreinforced restorations (p > 0.10), whereas reinforced resin-based restorations revealed significantly higher fracture loads (p < 0.01) than the unreinforced resin-based and PMMA provisional restorations.
引用
收藏
页码:447 / 450
页数:4
相关论文
共 9 条
[1]   LONGITUDINAL CLINICAL-EVALUATION OF FIBER-REINFORCED COMPOSITE FIXED PARTIAL DENTURES - A PILOT-STUDY [J].
ALTIERI, JV ;
BURSTONE, CJ ;
GOLDBERG, AJ ;
PATEL, AP .
JOURNAL OF PROSTHETIC DENTISTRY, 1994, 71 (01) :16-22
[2]   DENTURE BASE POLY(METHYL METHACRYLATE) REINFORCED WITH ULTRAHIGH MODULUS POLYETHYLENE FIBERS [J].
BRADEN, M ;
DAVY, KWM ;
PARKER, S ;
LADIZESKY, NH ;
WARD, IM .
BRITISH DENTAL JOURNAL, 1988, 164 (04) :109-113
[3]   THE EFFECT OF CARBON-FIBER ORIENTATION ON THE FATIGUE RESISTANCE AND BENDING PROPERTIES OF 2 DENTURE RESINS [J].
DEBOER, J ;
VERMILYEA, SG ;
BRADY, RE .
JOURNAL OF PROSTHETIC DENTISTRY, 1984, 51 (01) :119-121
[4]   THE USE OF CONTINUOUS FIBER REINFORCEMENT IN DENTISTRY [J].
GOLDBERG, AJ ;
BURSTONE, CJ .
DENTAL MATERIALS, 1992, 8 (03) :197-202
[5]  
JOSEPH ML, 1980, ESSENTIALS TEXTILES
[6]   FATIGUE FAILURE IN DENTURE BASE POLYMERS [J].
KELLY, E .
JOURNAL OF PROSTHETIC DENTISTRY, 1969, 21 (03) :257-&
[7]   ACRYLIC RESIN REINFORCED WITH CHOPPED HIGH-PERFORMANCE POLYETHYLENE FIBER - PROPERTIES AND DENTURE CONSTRUCTION [J].
LADIZESKY, NH ;
CHENG, YY ;
CHOW, TW ;
WARD, IM .
DENTAL MATERIALS, 1993, 9 (02) :128-135
[8]   PROSTHETIC USE OF CARBON FIBER-REINFORCED EPOXY-RESIN FOR AESTHETIC CROWNS AND FIXED PARTIAL DENTURES [J].
MALQUARTI, G ;
BERRUET, RG ;
BOIS, D .
JOURNAL OF PROSTHETIC DENTISTRY, 1990, 63 (03) :251-257
[9]   POLYMETHYLMETHACRYLATE REINFORCED WITH CARBON FIBRES [J].
SCHREIBER, CK .
BRITISH DENTAL JOURNAL, 1971, 130 (01) :29-+