Computerized provider order entry implementation: No association with increased mortality rates in an intensive care unit

被引:106
作者
Del Beccaro, MA [1 ]
Jeffries, HE [1 ]
Eisenberg, MA [1 ]
机构
[1] Childrens Hosp & Med Ctr, Seattle, WA 98105 USA
关键词
CPOE; ICU; mortality;
D O I
10.1542/peds.2006-0367
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
OBJECTIVE. Our goal was to determine if there were any changes in risk-adjusted mortality after the implementation of a computerized provider order entry system in our PICU. METHODS. Study was undertaken in a tertiary care PICU with 20 beds and 1100 annual admissions. Demographic, admission source, primary diagnosis, crude mortality, and Pediatric Risk of Mortality III risk-adjusted mortality were abstracted retrospectively on all admissions from the PICUEs database for the period October 1, 2002, to December 31, 2004. This time period reflects the 13 months before and 13 months after computerized provider order entry implementation. Pediatric Risk of Mortality III mortality risk adjustment was used to determine standardized mortality ratios. RESULTS. During the study period, 2533 patients were admitted to the PICU, of which 284 were transported from another facility. The 13-month preimplementation mortality rate was 4.22%, and the 13-month postimplementation mortality rate was 3.46%, representing a nonsignificant reduction in the risk of mortality in the postimplementation period. The standardized mortality ratio was 0.98 vs 0.77, respectively, and the mortality rate for the transported patients was 9.6% vs 6.29%. This yields a nonsignificant mortality risk reduction in the postimplementation period. The standardized mortality ratio was 1.10 preimplementation versus 0.70 postimplementation. Analysis of the 13-month preimplementation versus 5-month postimplementation periods showed a non-statistically significant trend in reduction of mortality for all PICU patients and for transported patients. CONCLUSIONS. Implementation of a computerized provider order entry system, even in the early months after implementation, was not associated with an increase in mortality. Our experience suggests that careful design, build, implementation, and support can mitigate the risk of implementing new technology even in an ICU setting.
引用
收藏
页码:290 / 295
页数:6
相关论文
共 12 条
  • [1] Specificity of computerized physician order entry has a significant effect on the efficiency of workflow for critically ill patients
    Ali, NA
    Mekhjian, HS
    Kuehn, PL
    Bentley, TD
    Kumar, R
    Ferketich, AK
    Hoffmann, SP
    [J]. CRITICAL CARE MEDICINE, 2005, 33 (01) : 110 - 114
  • [2] [Anonymous], 1999, ERR HUMAN BUILDING S
  • [3] Computerized physician order entry in US hospitals: Results of a 2002 survey
    Ash, JS
    Gorman, PN
    Seshadri, V
    Hersh, WR
    [J]. JOURNAL OF THE AMERICAN MEDICAL INFORMATICS ASSOCIATION, 2004, 11 (02) : 95 - 99
  • [4] Cheng C H, 2003, AMIA Annu Symp Proc, P150
  • [5] Impact of computerized physician order entry on clinical practice in a newborn intensive care unit
    Cordero L.
    Kuehn L.
    Kumar R.R.
    Mekhjian H.S.
    [J]. Journal of Perinatology, 2004, 24 (2) : 88 - 93
  • [6] Unexpected increased mortality after implementation of a commercially sold computerized physician order entry system
    Han, YY
    Carcillo, JA
    Venkataraman, ST
    Clark, RSB
    Watson, RS
    Nguyen, TC
    Bayir, H
    Orr, RA
    [J]. PEDIATRICS, 2005, 116 (06) : 1506 - 1512
  • [7] *KLAS ENT, 2005, CPOE DIG 2005
  • [8] Prospective observational study on the incidence of medication errors during simulated resuscitation in a paediatric emergency department
    Kozer, E
    Seto, W
    Verjee, Z
    Parshuram, C
    Khattak, S
    Koren, G
    Jarvis, DA
    [J]. BMJ-BRITISH MEDICAL JOURNAL, 2004, 329 (7478): : 1321 - 1324
  • [9] PHIBBS CS, PROVEN LINK CPOE MOR
  • [10] Computerized physician order entry and medication errors in a pediatric critical care unit
    Potts, AL
    Barr, FE
    Gregory, DF
    Wright, L
    Patel, NR
    [J]. PEDIATRICS, 2004, 113 (01) : 59 - 63