CT colonography at different radiation dose levels:: Feasibility of dose reduction

被引:133
作者
van Gelder, RE
Venema, HW
Serlie, IWO
Nio, CY
Determann, RM
Tipker, CA
Vos, FM
Glas, AS
Bartelsman, JFW
Bossuyt, PMM
Laméris, JS
Stoker, J
机构
[1] Univ Amsterdam, Acad Med Ctr, Dept Radiol, NL-1105 AZ Amsterdam, Netherlands
[2] Univ Amsterdam, Acad Med Ctr, Dept Med Phys, NL-1105 AZ Amsterdam, Netherlands
[3] Univ Amsterdam, Acad Med Ctr, Dept Clin Epidemiol & Biostat, NL-1105 AZ Amsterdam, Netherlands
[4] Univ Amsterdam, Acad Med Ctr, Dept Gastroenterol, NL-1105 AZ Amsterdam, Netherlands
[5] Tech Univ Delft, Dept Appl Phys, Pattern Recognit Grp, Delft, Netherlands
关键词
colon neoplasms; CT; colonoscopy; colon;
D O I
10.1148/radiol.2241011126
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To investigate the sensitivity and specificity of polyp detection and the image quality of computed tomographic (CT) colonography at different radiation dose levels and to study effective doses reported in literature on CT colonography. MATERIALS AND METHODS: CT colonography and colonoscopy were performed with 100 mAs in 50 consecutive patients at high risk for colorectal cancer; 50- and 30-mAs CT colonographic examinations were simulated with controlled addition of noise to raw transmission measurements. One radiologist randomly evaluated all original and simulated images for the presence of polyps and scored image quality. Differences in image quality were assessed with the Wilcoxon rank test. Scan protocols from the literature and recent (unpublished) updates were collected. RESULTS: In nine of 10 patients with polyps 5 mm in diameter or larger (sensitivity, 90%) and in seven of 17 patients with polyps smaller than 5 mm, polyps were correctly identified with CT colonography at all dose levels. Specificity for patients without polyps 5 mm or larger was 53%-60% at all dose levels and for patients without any polyps was 26% (at 100 and 50 mAs) and 48% (at 30 mAs). Image quality decreased significantly as the dose level decreased. The median effective doses (supine and prone positions) calculated from protocols reported in the literature and updates were 7.8 and 8.8 mSv, respectively. CONCLUSION: Although image quality decreases significantly at 30 mAs (3.6 mSv), polyp detection remains unimpaired. The median dose for CT colonography at institutions that perform CT colonographic research is currently 8.8 mSv. (C) RSNA, 2002.
引用
收藏
页码:25 / 33
页数:9
相关论文
共 29 条
[1]  
Angtuaco TL, 2001, AM J GASTROENTEROL, V96, P887
[2]   CT colonography without cathartic preparation: Feasibility study [J].
Callstrom, MR ;
Johnson, CD ;
Fletcher, JG ;
Reed, JE ;
Ahlquist, DA ;
Harmsen, WS ;
Tait, K ;
Wilson, LA ;
Corcoran, KE .
RADIOLOGY, 2001, 219 (03) :693-698
[3]   CT colonography with three-dimensional problem solving for detection of colonic polyps [J].
Dachman, AH ;
Kuniyoshi, JK ;
Boyle, CM ;
Samara, Y ;
Hoffmann, KR ;
Rubin, DT ;
Hanan, I .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (04) :989-995
[4]   Minimizing radiation dose for pediatric body applications of single-detector helical CT: Strategies at a large children's hospital [J].
Donnelly, LF ;
Emery, KH ;
Brody, AS ;
Laor, T ;
Gylys-Morin, VM ;
Anton, CG ;
Thomas, SR ;
Frush, DP .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (02) :303-306
[5]   A comparison of virtual and conventional colonoscopy for the detection of colorectal polyps [J].
Fenlon, HM ;
Nunes, DP ;
Schroy, PC ;
Barish, MA ;
Clarke, PD ;
Ferrucci, JT .
NEW ENGLAND JOURNAL OF MEDICINE, 1999, 341 (20) :1496-1503
[6]   Computed tomographic colonography: Current and future status for colorectal cancer screening [J].
Fletcher, JG ;
Johnson, CD .
SEMINARS IN ROENTGENOLOGY, 2000, 35 (04) :385-393
[7]   Optimization of CT colonography technique: Prospective trial in 180 patients [J].
Fletcher, JG ;
Johnson, CD ;
Welch, TJ ;
MacCarty, RL ;
Ahlquist, DA ;
Reed, JE ;
Harmsen, WS ;
Wilson, LA .
RADIOLOGY, 2000, 216 (03) :704-711
[8]   The influences of height and age on waist circumference as an index of adiposity in adults [J].
Han, TS ;
Seidell, JC ;
Currall, JEP ;
Morrison, CE ;
Deurenberg, P ;
Lean, MEJ .
INTERNATIONAL JOURNAL OF OBESITY, 1997, 21 (01) :83-89
[9]   Reducing data size and radiation dose for CT colonography [J].
Hara, AK ;
Johnson, CD ;
Reed, JE ;
Ahlquist, DA ;
Nelson, H ;
Ehman, RL ;
Harmsen, WS .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 168 (05) :1181-1184
[10]   Detection of colorectal polyps with CT colography: Initial assessment of sensitivity and specificity [J].
Hara, AK ;
Johnson, CD ;
Reed, JE ;
Ahlquist, DA ;
Nelson, H ;
MacCarty, RL ;
Harmsen, WS ;
Ilstrup, DM .
RADIOLOGY, 1997, 205 (01) :59-65