Image quality of a large area dynamic flat detector: Comparison with a state-of-the-art II/TV system

被引:10
作者
Bruijns, T [1 ]
Bastiaens, R [1 ]
Hoornaert, B [1 ]
von Reth, E [1 ]
Busse, F [1 ]
Heer, V [1 ]
Ducourant, T [1 ]
Cowen, A [1 ]
Davies, A [1 ]
Terrier, F [1 ]
机构
[1] Philips Med Syst, NL-5680 DA Best, Netherlands
来源
MEDICAL IMAGING 2002: PHYSICS OF MEDICAL IMAGING | 2002年 / 4682卷
关键词
D O I
10.1117/12.465574
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The purpose of this research is to establish the technical and clinical image quality of a 30x40 [cm(2)] dynamic medical x-ray flat detector (FD) compared to state-of-the-art Image Intensifier Television (II/TV) technology. The detector used was a Trixell Pixium 4700 designed for vascular and RF applications such as mixed fluoroscopy and radiography examinations. An RF system has been built which comprises both the FD, as well as an II/TV detector. This system enables a direct comparison of technical image quality measurements and patient images under exactly the same x-ray conditions. Comparison of clinical examinations on individual patients or groups of patients are possible. Image quality measurements performed comprise Detective Quantum Efficiency (including Modulation Transfer Function and Noise Power Spectrum), Disk Transfer Function and temporal artifacts. Observation tests, using Threshold Contrast Detail Detectability (TCDD) techniques, were also performed. Results show a DQE of the flat detector that is higher compared to II/TV and, above all, constant over a wide dose range. The II/TV DQE drops at higher dose range due to fixed pattern noise and CCD shot noise. Furthermore veiling glare (or flare) is substantially smaller in the FD-based system. TCDD subjective tests show improved system performance in favor of the FD system.
引用
收藏
页码:332 / 343
页数:2
相关论文
共 17 条
[1]   Technical and clinical results of an experimental Flat Dynamic (digital) X-ray image Detector (FDXD) system with real-time corrections [J].
Bruijns, TJC ;
Alving, PL ;
Baker, EL ;
Bury, R ;
Cowen, AR ;
Jung, N ;
Luijendijk, HA ;
Meulenbrugge, HJ ;
Stouten, HJ .
PHYSICS OF MEDICAL IMAGING, 1998, 3336 :33-44
[2]   Technical and clinical assessments of an experimental flat dynamic x-ray image detector system [J].
Bruijns, TJC ;
Bury, R ;
Busse, F ;
Davies, AG ;
Cowen, AR ;
Rütten, W ;
Reitsma, H .
MEDICAL IMAGING 1999: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 1999, 3659 :324-335
[3]   Technical report: Initial experiences with an experimental solid-state universal digital X-ray image detector [J].
Bury, RF ;
Cowen, AR ;
Davies, AG ;
Baker, EL ;
Hawkridge, P ;
Bruijns, AJC ;
Reitsma, H .
CLINICAL RADIOLOGY, 1998, 53 (12) :923-928
[4]  
BUSSE F, 1998, IMAGE QUALITY PROTOT
[5]  
BUSSE F, 2001, SPIE MED IMAGING PHY
[6]  
CHAUSSAT C, 1998, P SPIE
[7]  
Cowen A. R., 1994, AM ASS PHYSICISTS ME, V20, P499
[8]  
DAVIES, 1999, SPIE MED IMAGING IMA
[9]  
DUCOURANT T, 2000, SPIE MED IMAGING PHY, P3977
[10]   Performance characteristics of an amorphous silicon flat panel X-ray imaging detector [J].
Granfors, PR .
MEDICAL IMAGING 1999: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 1999, 3659 :480-490