Theory and application of static field inhomogeneity effects in gradient-echo imaging

被引:232
作者
Reichenbach, JR
Venkatesan, R
Yablonskiy, DA
Thompson, MR
Lai, S
Haacke, EM
机构
[1] Mallinckrodt Institute of Radiology, Washington University, St. Louis, MO 63110
[2] Dept. of Biomed. and Biol. Eng., Washington University, St. Louis
[3] Department of Physics, Case Western Reserve University, Cleveland
[4] Lucas MRS Imaging Center, Stanford University, Stanford
来源
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING | 1997年 / 7卷 / 02期
关键词
artifact; rapid imaging; phase imaging; K space; image processing; brain;
D O I
10.1002/jmri.1880070203
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The influence of local static magnetic field inhomogeneities on gradient-echo imaging is discussed and the underlying theoretical aspects are reviewed, A high-resolution approach is suggested to suppress image distortion and restore signal loss due to spin dephasing. Acquisition of three-dimensional data sets not only overcomes part of the limitations associated with gradient echoes but also makes it possible to extract local information about the strength or direction of background gradients and relative susceptibility changes between different tissues. Applications of the suggested approach in the human brain for anatomical imaging as well as for extraction of physical and physiological parameters are presented and discussed.
引用
收藏
页码:266 / 279
页数:14
相关论文
共 23 条
[1]   NUMERICAL-ANALYSIS OF THE MAGNETIC-FIELD FOR ARBITRARY MAGNETIC-SUSCEPTIBILITY DISTRIBUTIONS IN 2D [J].
BHAGWANDIEN, R ;
VANEE, R ;
BEERSMA, R ;
BAKKER, CJG ;
MOERLAND, MA ;
LAGENDIJK, JJW .
MAGNETIC RESONANCE IMAGING, 1992, 10 (02) :299-313
[2]   NMR CHEMICAL-SHIFT IMAGING IN 3 DIMENSIONS [J].
BROWN, TR ;
KINCAID, BM ;
UGURBIL, K .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA-BIOLOGICAL SCIENCES, 1982, 79 (11) :3523-3526
[3]   REDUCTION OF SUSCEPTIBILITY ARTIFACT IN GRADIENT-ECHO IMAGING [J].
CHO, ZH ;
RO, YM .
MAGNETIC RESONANCE IN MEDICINE, 1992, 23 (01) :193-200
[4]   Functional MR imaging using gradient-echo echo-planar imaging in the presence of large static field inhomogeneities [J].
Constable, RT .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (06) :746-752
[5]   THE EFFECTS OF INTRAVOXEL DEPHASING AND INCOMPLETE SLICE REFOCUSING ON SUSCEPTIBILITY CONTRAST IN GRADIENT-ECHO MRI [J].
FRAHM, J ;
MERBOLDT, KD ;
HANICKE, W .
JOURNAL OF MAGNETIC RESONANCE SERIES B, 1995, 109 (02) :234-237
[6]   DIRECT FLASH MR IMAGING OF MAGNETIC-FIELD INHOMOGENEITIES BY GRADIENT COMPENSATION [J].
FRAHM, J ;
MERBOLDT, KD ;
HANICKE, W .
MAGNETIC RESONANCE IN MEDICINE, 1988, 6 (04) :474-480
[7]   FUNCTIONAL MRI OF HUMAN BRAIN ACTIVATION AT HIGH SPATIAL-RESOLUTION [J].
FRAHM, J ;
MERBOLDT, KD ;
HANICKE, W .
MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (01) :139-144
[8]   REDUCTION OF T2-STAR DEPHASING IN GRADIENT FIELD ECHO IMAGING [J].
HAACKE, EM ;
TKACH, JA ;
PARRISH, TB .
RADIOLOGY, 1989, 170 (02) :457-462
[9]   THE EFFECTS OF FINITE SAMPLING IN SPIN-ECHO OR FIELD-ECHO MAGNETIC-RESONANCE-IMAGING [J].
HAACKE, EM .
MAGNETIC RESONANCE IN MEDICINE, 1987, 4 (05) :407-421
[10]   IN-VIVO VALIDATION OF THE BOLD MECHANISM - A REVIEW OF SIGNAL CHANGES IN GRADIENT-ECHO FUNCTIONAL MRI IN THE PRESENCE OF FLOW [J].
HAACKE, EM ;
LAI, S ;
YABLONSKIY, DA ;
LIN, WL .
INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 1995, 6 (2-3) :153-163