Clinical usefulness of ECG-gated 18F-FDG PET combined with 99mTc-MIBI gated SPECT for evaluating myocardial viability and function

被引:28
作者
Yamakawa, Y
Takahashi, N
Ishikawa, T
Uchino, K
Mochida, Y
Ebina, T
Kobayashi, T
Matsushita, K
Matsumoto, K
Kawasaki, N
Shimura, M
Ohkusu, Y
Sumita, S
Kimura, K
Inoue, T
Umemura, S
机构
[1] Yokohama City Univ, Sch Med, Dept Internal Med 2, Kanazawa Ku, Yokohama, Kanagawa 2360004, Japan
[2] Yokohama City Univ, Sch Med, Dept Radiol, Yokohama, Kanagawa 2360004, Japan
关键词
gated FDG PET; gated MIBI SPECT; myocardial viability; myocardial function;
D O I
10.1007/BF02984480
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study sought to evaluate an imaging approach using gated Tc-99m-MIBI (MIBI) SPECT and gated F-18-FDG (FDG) PET for assessment of myocardial viability and cardiac function. Methods: Forty-eight patients (38 men, mean age 68.1 +/- 9.6 years) underwent ECG-gated FDG PET and MIBI SPECT within a week. The baseline diagnoses were coronary artery disease (3 1), mitral regurgitation (1), paroxysmal arrhythmia (10), and dilated cardiomyopathy (6). The gated FDG PET data were analyzed using pFAST software, and the gated MIBI SPECT data were analyzed using QGS software. Fifteen patients were diagnosed with myocardial infarction, and follow-up study was performed to assess the functional outcome four months later. An improvement in LVEF of >5% was defined as significant. The LV myocardium was divided into 17 segments, and regional defect scores were visually assessed using a 4-point scale for each segment (0 = normal, 1 = mildly reduced, 2 = moderately reduced, 3 = absent). A segment with a greater defect score on MIBI SPECT than on FDG PET was defined as a mismatch. The patients were divided into two groups: those with at least two mismatched segments (MM-group), and those with none or one (M-group). Results: LVEF, EDV and ESV measured by gated FDG PET were highly correlated with those obtained by gated MIBI SPECT (r = 0.848, 0.855 and 0.911, p < 0.0001, respectively). The mean values of LVEF did not differ significantly, but EDV and ESV obtained by gated FDG PET were significantly grater than those obtained by gated MIBI SPECT (p < 0.0001). In 15 patients diagnosed with myocardial infarction, a significant association (p < 0.05) was found between the relative uptake of FDG PET and MIBI SPECT and the functional outcome 4 months later. Global LV function improved in 6 of the 8 patients showing mismatch but in only 1 of the 7 patients with matched defects, resulting in a sensitivity of 86% and specificity of 75%. The overall accuracy to predict global functional outcome was high (80%). Conclusion: This imaging approach allows accurate evaluation of myocardial viability. Furthermore, the high correlations of gated FDG PET and gated MIBI SPECT measurements hold promise for the assessment of left ventricular function using gated FDG PET.
引用
收藏
页码:375 / 383
页数:9
相关论文
共 31 条
[1]   An investigation of the estimation of ejection fractions and cardiac volumes by a quantitative gated SPECT software package in simulated gated SPECT images [J].
Achtert, AD ;
King, MA ;
Dahlberg, ST ;
Pretorius, PH ;
LaCroix, KJ ;
Tsui, BMW .
JOURNAL OF NUCLEAR CARDIOLOGY, 1998, 5 (02) :144-152
[2]  
ALTEHOEFER C, 1992, EUR J NUCL MED, V19, P334
[3]   REVERSIBLE ASYNERGY - HISTOPATHOLOGIC AND ELECTROGRAPHIC CORRELATIONS IN PATIENTS WITH CORONARY-ARTERY DISEASE [J].
BODENHEIMER, MM ;
BANKA, VS ;
HERMANN, GA ;
TROUT, RG ;
PASDAR, H ;
HELFANT, RH .
CIRCULATION, 1976, 53 (05) :792-796
[4]   MYOCARDIAL STUNNING IN MAN [J].
BOLLI, R .
CIRCULATION, 1992, 86 (06) :1671-1691
[5]   END-SYSTOLIC VOLUME AS A PREDICTOR OF POSTOPERATIVE LEFT-VENTRICULAR PERFORMANCE IN VOLUME OVERLOAD FROM VALVULAR REGURGITATION [J].
BOROW, KM ;
GREEN, LH ;
MANN, T ;
SLOSS, LJ ;
BRAUNWALD, E ;
COLLINS, JJ ;
COHN, L ;
GROSSMAN, W .
AMERICAN JOURNAL OF MEDICINE, 1980, 68 (05) :655-663
[6]   IMPROVED REGIONAL VENTRICULAR-FUNCTION AFTER SUCCESSFUL SURGICAL REVASCULARIZATION [J].
BRUNDAGE, BH ;
MASSIE, BM ;
BOTVINICK, EH .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1984, 3 (04) :902-908
[7]   Clinical validation of three-dimensional color-modulated displays of myocardial perfusion [J].
Cooke, CD ;
Vansant, JP ;
Krawczynska, EG ;
Faber, TL ;
Garcia, EV .
JOURNAL OF NUCLEAR CARDIOLOGY, 1997, 4 (02) :108-116
[8]   Recovery of regional left ventricular dysfunction after coronary revascularization - Impact of myocardial viability assessed by nuclear imaging and vessel patency at follow-up angiography [J].
Dahl, JV ;
Altehoefer, C ;
Sheehan, FH ;
Buechin, P ;
Uebis, R ;
Messmer, BJ ;
Buell, U ;
Hanrath, P .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 28 (04) :948-958
[9]   Left ventricular ejection fraction and volumes from gated single photon emission tomographic myocardial perfusion images: Comparison between two algorithms working in three-dimensional space [J].
Everaert, H ;
Bossuyt, A ;
Franken, PR .
JOURNAL OF NUCLEAR CARDIOLOGY, 1997, 4 (06) :472-476
[10]  
Faber TL, 1999, J NUCL MED, V40, P650