Renal artery stenosis: Grading of hemodynamic changes with cine phase-contrast MR blood flow measurements

被引:117
作者
Schoenberg, SO
Knopp, MV
Bock, M
Kallinowski, F
Just, A
Essig, M
Hawighorst, H
Schad, L
vanKaick, G
机构
[1] UNIV HEIDELBERG HOSP, DEPT SURG, DIV VASC SURG, HEIDELBERG, GERMANY
[2] UNIV HEIDELBERG, DEPT PHYSIOL 1, D-6900 HEIDELBERG, GERMANY
关键词
renal arteries; flow dynamics; MR; stenosis or obstruction; US;
D O I
10.1148/radiology.203.1.9122415
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To analyze the blood flow dynamics in renal artery stenosis with high-temporal-resolution cine phase-contrast magnetic resonance (MR) flow measurements. MATERIALS AND METHODS: Cine phase-contrast MR flow measurements were invasively validated with real-time intraoperative transit-time ultrasound (US). In 23 patients, 48 renal artery stenoses were confirmed at digital subtraction angiography. Cardiac-gated cine phase-contrast MR flow measurements were obtained in 32-msec intervals, and flow curves were calculated for the whole cardiac cycle. Hemodynamic parameters evaluated included the decrease in mean flow and the delay and reduction in the systolic velocity maximum due to decrease in or absence of the early systolic peak. RESULTS: Overall differentiation between renal artery stenosis (n = 31) and nonstenosed vessels (n = 17) with cine phase-contrast MR revealed a sensitivity of 90% and specificity of 94% compared with findings at digital subtraction angiography. High-grade stenoses (>50%, n = 19) were detected with cine phase-contrast MR with sensitivity of 100% and specificity of 93%. CONCLUSION: Quantitative and qualitative analysis of cardiac-gated cine phase-contrast MR flow velocity curves provided a highly accurate method to detect hemodynamic abnormalities in patients with suspected renal artery stenosis.
引用
收藏
页码:45 / 53
页数:9
相关论文
共 36 条
[1]  
[Anonymous], 1987, ARCH INTERN MED, V147, P820
[2]   NONINVASIVE DIAGNOSIS OF RENAL-ARTERY STENOSIS BY ECHO-DOPPLER VELOCIMETRY [J].
AVASTHI, PS ;
VOYLES, WF ;
GREENE, ER .
KIDNEY INTERNATIONAL, 1984, 25 (05) :824-829
[3]  
BASS JC, 1995, RADIOLOGY, V197, P421
[4]   ROLE OF ENDOTHELIUM-DERIVED RELAXING FACTOR IN RENAL AUTOREGULATION IN CONSCIOUS DOGS [J].
BAUMANN, JE ;
PERSSON, PB ;
EHMKE, H ;
NAFZ, B ;
KIRCHHEIM, HR .
AMERICAN JOURNAL OF PHYSIOLOGY, 1992, 263 (02) :F208-F213
[5]   RENAL-ARTERY STENOSIS - PROSPECTIVE EVALUATION OF DIAGNOSIS WITH COLOR DUPLEX US COMPARED WITH ANGIOGRAPHY - WORK IN PROGRESS [J].
BERLAND, LL ;
KOSLIN, DB ;
ROUTH, WD ;
KELLER, FS .
RADIOLOGY, 1990, 174 (02) :421-423
[6]   MEASUREMENT OF FLOW WITH NMR IMAGING USING A GRADIENT PULSE AND PHASE DIFFERENCE TECHNIQUE [J].
BRYANT, DJ ;
PAYNE, JA ;
FIRMIN, DN ;
LONGMORE, DB .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1984, 8 (04) :588-593
[7]   PULSUS TARDUS - ITS CAUSE AND POTENTIAL LIMITATIONS IN DETECTION OF ARTERIAL-STENOSIS [J].
BUDE, RO ;
RUBIN, JM ;
PLATT, JF ;
FECHNER, KP ;
ADLER, RS .
RADIOLOGY, 1994, 190 (03) :779-784
[8]   A WEIGHTED LEAST-SQUARES METHOD FOR NUCLEAR-MAGNETIC-RESONANCE VELOCITY IMAGING [J].
CAPRIHAN, A ;
ICENOGLE, MV .
MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (04) :512-520
[9]   PREDICTIVE VALUE OF EXERCISE RENOGRAPHY FOR PRESURGICAL EVALUATION OF NEPHROGENIC HYPERTENSION [J].
CLORIUS, JH ;
ALLENBERG, J ;
HUPP, T ;
STRAUSS, LG ;
SCHMIDLIN, P ;
IRNGARTINGER, G ;
WAGNER, R ;
MUKHOPADHYAY, C .
HYPERTENSION, 1987, 10 (03) :280-286
[10]   RENAL-ARTERY BLOOD-FLOW - QUANTITATION WITH PHASE-CONTRAST MR-IMAGING WITH AND WITHOUT BREATH-HOLDING [J].
DEBATIN, JF ;
TING, RH ;
WEGMULLER, H ;
SOMMER, FG ;
FREDRICKSON, JO ;
BROSNAN, TJ ;
BOWMAN, BS ;
MYERS, BD ;
HERFKENS, RJ ;
PELC, NJ .
RADIOLOGY, 1994, 190 (02) :371-378