Accuracy of computed tomography in assessing thoracic pedicle screw malposition

被引:27
作者
Fayyazi, AH
Hugate, RR
Pennypacker, J
Gelb, DE
Ludwig, SC
机构
[1] Univ Maryland, Dept Orthopaed, Baltimore, MD 21201 USA
[2] SUNY Upstate Med Univ, Inst Spine Care, Dept Orthoped Surg, Syracuse, NY USA
[3] Milton S Hershey Med Ctr, Dept Orthopaed & Rehabil, Hershey, PA USA
来源
JOURNAL OF SPINAL DISORDERS & TECHNIQUES | 2004年 / 17卷 / 05期
关键词
thoracic spine; pedicle screw; computed tomography; reliability; accuracy;
D O I
10.1097/01.bsd.0000112049.36255.bc
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: Transpedicular instrumentation of the thoracic spine is potentially dangerous because of the close proximity of vital structures and the morphologic variability seen. Computed tomography has become the gold standard in evaluating the position of thoracic pedicle screws in vivo. Unfortunately, despite its common use, the accuracy of computed tomography has not been adequately investigated. The objective of this work was to evaluate the accuracy of computed tomography in evaluating the position of thoracic pedicle screws. Methods: One hundred ninety-four thoracic pedicles in nine cadaveric specimens were instrumented and evaluated postoperatively with computed tomography and open dissection. Computed tomography films were assessed by three blinded observers who noted the position of each pedicle screw on two separate occasions. These data were subsequently compared with the open dissection data. Results: Computed tomography was found to be 76 +/- 16% sensitive and 75 +/- 13% specific when compared with open dissection. Overall accuracy was 76 +/- 8%. Intraobserver accuracy was 79 +/- 5% in assessing thoracic pedicle screws by computed tomography. Fair to moderate degree of agreement was demonstrated for both interobserver and intraobserver data using kappa values. Conclusions: Computed tomography was found to be relatively insensitive in assessing thoracic pedicle screw position. In the face of postoperative complications, surgical exploration and hardware removal may still be necessary despite negative computed tomography.
引用
收藏
页码:367 / 371
页数:5
相关论文
共 8 条
[1]   In vivo accuracy of thoracic pedicle screws [J].
Belmont, PJ ;
Klemme, WR ;
Dhawan, A ;
Polly, DW .
SPINE, 2001, 26 (21) :2340-2346
[2]  
Berlemann U, 1997, J SPINAL DISORD, V10, P117
[3]   Segmental pedicle screw instrumentation in idiopathic thoracolumbar and lumbar scoliosis [J].
Halm, H ;
Niemeyer, T ;
Link, T ;
Liljenqvist, U .
EUROPEAN SPINE JOURNAL, 2000, 9 (03) :191-197
[4]  
Jonsson B, 1996, Eur Spine J, V5, P36, DOI 10.1007/BF00307825
[5]   Comparison of computerized tomography and direct visualization in thoracic pedicle screw placement [J].
Rao, G ;
Brodke, DS ;
Rondina, M ;
Dailey, AT .
JOURNAL OF NEUROSURGERY, 2002, 97 (02) :223-226
[6]   PLACEMENT OF PEDICLE SCREWS IN THE THORACIC SPINE .2. AN ANATOMICAL AND RADIOGRAPHIC ASSESSMENT [J].
VACCARO, AR ;
RIZZOLO, SJ ;
BALDERSTON, RA ;
ALLARDYCE, TJ ;
GARFIN, SR ;
DOLINSKAS, C ;
AN, HS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1995, 77A (08) :1200-1206
[7]  
WEINSTEIN JN, 1992, CLIN ORTHOP RELAT R, P34
[8]   Accuracy of using computed tomography to identify pedicle screw placement in cadaveric human lumbar spine [J].
Yoo, JU ;
Ghanayem, A ;
Petersilge, C ;
Lewin, J .
SPINE, 1997, 22 (22) :2668-2671