Purpose: To evaluate the efficacy and safety of subselective arterial embolization with polyvinyl alcohol (PVA) particles with or without microcoil augmentation to control postoperative lower gastrointestinal (GI) bleeding. Methods: Ten patients with clinical, scintigraphic, and angiographic evidence of postoperative lower GI bleeding were considered for subselective embolization. Subselective embolizations were performed through coaxial microcatheters with 355-500 mu m PVA particles with or without additional coil embolization. Results: Embolization was technically successful in 9 of 10 (90%) patients. In one patient, subselective embolization was not possible; consequently no embolization was performed. Clinical success was achieved after a single embolization in 6 of 10 (60%) patients and after a second embolization in an additional 3 of the 10 (30%) patients. While there was no rebleeding in patients with normal coagulation parameters, all three patients (100%) with coagulopathy rebled, two of them from another source. Although no acute ischemic effects developed, no long-term sequela such as ischemic stricture were specifically looked for. Seven patients developed abdominal discomfort and/or fever within 24-48 hr. Four of 10 patients died of complications other than hemorrhage or ischemia, Conclusion: Subselective PVA embolization with or without a microcoil embolization is an effective and safe means of managing postoperative lower GI hemorrhage in patients with multiorgan trauma.