RELIABILITY AND SIZE OF THE MEASUREMENT ERROR WHEN DETERMINING THE CROSS-SECTIONAL AREA OF THE TIBIAL NERVE AT THE TARSAL TUNNEL WITH ULTRASONOGRAPHY

被引:51
作者
Alshami, Ali M. [1 ]
Cairns, Craig W. [2 ]
Wylie, Bridie K. [3 ]
Souvlis, Tina [1 ]
Coppieters, Michel W. [1 ]
机构
[1] Univ Queensland, Sch Hlth & Rehabil Sci, Brisbane, Qld 4072, Australia
[2] Queensland Xray, Mt Gravatt, Qld, Australia
[3] Qscan Radiol Clin, Windsor, Qld, Australia
关键词
Compression neuropathy; Entrapment neuropathy; Plantar heel pain; Reliability; Tarsal tunnel syndrome; Ultrasound; CARPAL-TUNNEL; DIAGNOSIS; SONOGRAPHY; ULTRASOUND; PINCH;
D O I
10.1016/j.ultrasmedbio.2009.01.011
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
An in depth analysis of the reliability of ultrasonography to measure the cross-sectional area of the tibial nerve or any other peripheral nerve is not available in the literature. This study determined the reliability and size of the measurement error of high-resolution ultrasound to measure the size of the tibial nerve at the tarsal tunnel. The cross-sectional area of the tibial nerve was measured by two experienced sonographers at 1 cm proximal to the medial malleolus. Measurements were made in 10 healthy participants without plantar heel pain. Intra and intertester reliability were determined by calculation of intraclass correlation coefficients (ICC), measurement error magnitude and smallest detectable difference (SDD). A direct (tracing) and indirect (ellipsoid formula) method were evaluated. Results demonstrated that the intra and intertester reliability were excellent (ICC, all >= 0.86). The measurement error and SDD were 2 very small, especially when measurements from three scans were averaged (measurement error: 0.44.9 mm(2); SDD: 1.1-2.5 mm(2)). The findings of this study support the view that high-resolution ultrasound is reliable to measure the cross-sectional area of a peripheral nerve. As a result of the small measurement error, a side-to-side difference as small as -1.8 mm(2) can be interpreted meaningfully in an individual patient. This difference is much smaller than the swelling reported in the literature for patients with tibial neuropathy. (E-mail: m.coppieters@uq.edu.au) (C) 2009 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:1098 / 1102
页数:5
相关论文
共 24 条
[1]  
Abicalaf CA, 2007, CLIN RADIOL, V62, P891, DOI 10.1016/j.crad.2007.01.029
[2]   Sonographic evaluation of the carpal tunnel after provocative exercises [J].
Altinok, MT ;
Baysal, O ;
Karakas, HM ;
Firat, AK .
JOURNAL OF ULTRASOUND IN MEDICINE, 2004, 23 (10) :1301-1306
[3]  
Baumgartner T., 2006, Measurement Theory and Practice in Kinesiology, P27
[4]   High-resolution sonography of the peripheral nervous system - a review of the literature [J].
Beekman, R ;
Visser, LH .
EUROPEAN JOURNAL OF NEUROLOGY, 2004, 11 (05) :305-314
[5]  
Bilge O., 2003, Neuroanatomy, V2, P39
[6]   CARPAL-TUNNEL SYNDROME - DIAGNOSIS WITH HIGH-RESOLUTION SONOGRAPHY [J].
BUCHBERGER, W ;
JUDMAIER, W ;
BIRBAMER, G ;
LENER, M ;
SCHMIDAUER, C .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1992, 159 (04) :793-798
[7]   Sonography in the diagnosis of carpal tunnel syndrome [J].
Duncan, I ;
Sullivan, P ;
Lomas, F .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 173 (03) :681-684
[8]  
HAAS M, 1991, J MANIP PHYSIOL THER, V14, P119
[9]   Nerves in a pinch: imaging of nerve compression syndromes [J].
Hochman, MG ;
Zilberfarb, JL .
RADIOLOGIC CLINICS OF NORTH AMERICA, 2004, 42 (01) :221-+
[10]   Ultrasonography of the tibial nerve in vasculitic neuropathy [J].
Ito, Takao ;
Kijima, Masanori ;
Watanabe, Takashi ;
Sakuta, Manabu ;
Nishiyama, Kazutoshi .
MUSCLE & NERVE, 2007, 35 (03) :379-382