Quantitation of SR 27417 in human plasma using electrospray liquid chromatography tandem mass spectrometry: A study of ion suppression

被引:316
作者
Buhrman, DL [1 ]
Price, PI [1 ]
Rudewicz, PJ [1 ]
机构
[1] SANOFI WINTHROP,MALVERN,PA
关键词
D O I
10.1016/S1044-0305(96)00072-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The effect of coeluting matrix compounds on the quantitation of SR 27417 in human plasma using electrospray liquid chromatography-tandem mass spectrometry has been examined. During the method development stage of this assay, plasma samples spiked with the analyte at 100 pg/mL were extracted using three different procedures: a hexane liquid-liquid extraction, an ethyl acetate back-extraction, and a solid phase extraction. Ion intensity of the analyte was found to be related inversely to the percent ionization of coeluting matrix components as evidenced by full scan spectra. The ethyl acetate back-extraction, which contained the fewest coeluting components, resulted in the highest ion intensity for the analyte. An assay comparison was done by using the liquid-liquid hexane and the ethyl acetate back-extractions for sample preparation. Replicate 1-mL, samples (n = 5) at 11 concentrations from 5 to 2000 pg/mL were extracted and analyzed. The results for the ethyl acetate back-extracted samples were acceptable from 2000 to 5 pg/mL with accuracy ranging from -11.6 to 2.61% of the nominal concentrations. In contrast, the hexane liquid-liquid method had poor accuracy and precision below 20 pg/mL. The difference is explained by suppression of analyte ion intensity. These results are consistent with the current theory of electrospray ionization. (C) 1996 American Society for Mass Spectrometry
引用
收藏
页码:1099 / 1105
页数:7
相关论文
共 8 条
  • [1] BRUINS AP, 1995, P 7 SAN C MASS SPECT
  • [2] INVESTIGATIONS OF THE ELECTROSPRAY INTERFACE FOR LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY
    IKONOMOU, MG
    BLADES, AT
    KEBARLE, P
    [J]. ANALYTICAL CHEMISTRY, 1990, 62 (09) : 957 - 967
  • [3] THE SENSITIVE DETERMINATION OF ABANOQUIL IN BLOOD BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY ATMOSPHERIC-PRESSURE IONIZATION MASS-SPECTROMETRY
    KAYE, B
    CLARK, MWH
    CUSSANS, NJ
    MACRAE, PV
    STOPHER, DA
    [J]. BIOLOGICAL MASS SPECTROMETRY, 1992, 21 (11) : 585 - 589
  • [4] FROM IONS IN SOLUTION TO IONS IN THE GAS-PHASE - THE MECHANISM OF ELECTROSPRAY MASS-SPECTROMETRY
    KEBARLE, P
    TANG, L
    [J]. ANALYTICAL CHEMISTRY, 1993, 65 (22) : A972 - A986
  • [5] DETERMINATION OF XANOMELINE IN HUMAN PLASMA BY IONSPRAY TANDEM MASS-SPECTROMETRY
    MURPHY, AT
    BONATE, PL
    KASPER, SC
    GILLESPIE, TA
    DELONG, AF
    [J]. BIOLOGICAL MASS SPECTROMETRY, 1994, 23 (10) : 621 - 625
  • [6] Steiner F., 1991, APPL NARROW BORE COL
  • [7] FIELD-INDUCED ION EVAPORATION FROM LIQUID SURFACES AT ATMOSPHERIC-PRESSURE
    THOMSON, BA
    IRIBARNE, JV
    [J]. JOURNAL OF CHEMICAL PHYSICS, 1979, 71 (11) : 4451 - 4463
  • [8] DETERMINATION OF BOLDENONE SULFOCONJUGATE AND RELATED STEROID SULFATES IN EQUINE URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY TANDEM MASS-SPECTROMETRY
    WEIDOLF, LOG
    LEE, ED
    HENION, JD
    [J]. BIOMEDICAL AND ENVIRONMENTAL MASS SPECTROMETRY, 1988, 15 (05): : 283 - 289