Validity of the Walked Distance Estimated by Wearable Devices in Stroke Individuals

被引:20
作者
Compagnat, Maxence [1 ,2 ]
Batcho, Charles Sebiyo [3 ,4 ]
David, Romain [2 ]
Vuillerme, Nicolas [5 ]
Salle, Jean Yves [1 ,2 ]
Daviet, Jean Christophe [1 ,2 ]
Mandigout, Stephane [1 ]
机构
[1] Univ Limoges, Environm HAVAE EA6310, Handicap, Aging,Auton, F-87042 Limoges, France
[2] Univ Hosp Ctr Limoges, Dept Phys Med & Rehabil, F-87042 Limoges, France
[3] CIUSSS CN, Ctr Interdisciplinary Res Rehabil & Social Integr, Quebec City, PQ G1M 2S8, Canada
[4] Univ Laval, Fac Med, Dept Rehabil, Quebec City, PQ G1M 2S8, Canada
[5] Univ Grenoble Alpes, AGEIS, F-38041 Grenoble 9, France
关键词
accelerometry; wearable electronic devices; validity; walking; physical activity; PHYSICAL-ACTIVITY; COMMUNITY AMBULATION; ACTIVITY MONITORS; MEASURING STEPS; ACCELEROMETER; PEDOMETERS; ACCURACY; REQUIREMENTS; RELIABILITY; SURVIVORS;
D O I
10.3390/s19112497
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background: Health professionals need valid devices to assess a stroke individual's ability to walk. The aim was to evaluate the validity of the estimation of the walked distance by wearable devices and the impact of the sensor's position in stroke individuals. Methods: Post-stroke patients able to walk without human assistance were equipped with several wearable devices: pedometers, Actigraph, and Sensewear Armband placed according to the manufacturers' recommendations. Participants walked for 6 min at a comfortable speed wearing all sensors at the same time. We analyzed the validity of sensor-estimated distances according to their position using Bland-Altman analysis, root-mean-square error, and coefficient of correlation. Results: In total, 35 individuals were included (mean age = 65 +/- 15 years). The best estimations were given by the Actigraph worn on the unaffected ankle (mean bias (MB) = 22.6 +/- 32.4 m; p = 0.37) and by the pedometer worn on the unaffected hip (MB = 20.5 +/- 24.6 m; p = 0.46). The other sensors and positions provided large estimation errors over 95 m (p < 0.05). Conclusion: This study led to a recommendation of a pedometer worn on the unaffected hip or an Actigraph worn on the unaffected ankle to get a valid estimation of the distance walked by stroke individuals.
引用
收藏
页数:11
相关论文
共 38 条
[1]   Update on Distance and Velocity Requirements for Community Ambulation [J].
Andrews, A. Williams ;
Chinworth, Susan A. ;
Bourassa, Michael ;
Garvin, Miranda ;
Benton, Dacia ;
Tanner, Scott .
JOURNAL OF GERIATRIC PHYSICAL THERAPY, 2010, 33 (03) :128-134
[2]   Stroke patients' functions in personal activities of daily living in relation to sleep and socio-demographic and clinical variables in the acute phase after first-time stroke and at six months of follow-up [J].
Bakken, Linda N. ;
Kim, Hesook S. ;
Finset, Arnstein ;
Lerdal, Anners .
JOURNAL OF CLINICAL NURSING, 2012, 21 (13-14) :1886-1895
[3]   Variability in spatiotemporal step characteristics and its relationship to walking performance post-stroke [J].
Balasubramanian, Chitralakshmi K. ;
Neptune, Richard R. ;
Kautz, Steven A. .
GAIT & POSTURE, 2009, 29 (03) :408-414
[4]   Interventions for improving community ambulation in individuals with stroke [J].
Barclay, Ruth E. ;
Stevenson, Ted J. ;
Poluha, William ;
Ripat, Jacquie ;
Nett, Cristabel ;
Srikesavan, Cynthia S. .
COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2015, (03)
[5]   Accelerometer-based Physical Activity: Total Volume per Day and Standardized Measures [J].
Bassett, David R. ;
Troiano, Richard P. ;
Mcclain, James J. ;
Wolff, Dana L. .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2015, 47 (04) :833-838
[6]   Physical Activity and Exercise Recommendations for Stroke Survivors A Statement for Healthcare Professionals From the American Heart Association/American Stroke Association [J].
Billinger, Sandra A. ;
Arena, Ross ;
Bernhardt, Julie ;
Eng, Janice J. ;
Franklin, Barry A. ;
Johnson, Cheryl Mortag ;
MacKay-Lyons, Marilyn ;
Macko, Richard F. ;
Mead, Gillian E. ;
Roth, Elliot J. ;
Shaughnessy, Marianne ;
Tang, Ada .
STROKE, 2014, 45 (08) :2532-2553
[7]   INTERRATER RELIABILITY OF A MODIFIED ASHWORTH SCALE OF MUSCLE SPASTICITY [J].
BOHANNON, RW ;
SMITH, MB .
PHYSICAL THERAPY, 1987, 67 (02) :206-207
[8]  
Brun V, 2000, Ann Readapt Med Phys, V43, P14, DOI [10.1016/S0168-6054(00)87937-4, DOI 10.1016/S0168-6054(00)87937-4, 10.1016/s0168-6054(00)87937-4]
[9]   The Use of Pedometers in Stroke Survivors: Are They Feasible and How Well Do They Defect Steps? [J].
Carroll, Sarah L. ;
Greig, Carolyn A. ;
Lewis, Susan J. ;
McMurdo, Marion E. ;
Sniehotta, Falko F. ;
Johnston, Marie ;
Johnston, Derek W. ;
Scopes, Judy ;
Mead, Gillian E. .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2012, 93 (03) :466-470
[10]   Gait differences between individuals with post-stroke hemiparesis and non-disabled controls at matched speeds [J].
Chen, G ;
Patten, C ;
Kothari, DH ;
Zajac, FE .
GAIT & POSTURE, 2005, 22 (01) :51-56