Visual and colorimetric lithium ion sensing based on digital color analysis

被引:61
作者
Hirayama, E
Sugiyama, T
Hisamoto, H
Suzuki, K
机构
[1] Keio Univ, Dept Appl Chem, Kohoku Ku, Yokohama, Kanagawa 2238522, Japan
[2] Kanagawa Acad Sci & Technol, Takatsu Ku, Kawasaki, Kanagawa 2130012, Japan
关键词
D O I
10.1021/ac990588w
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new optical analytical method, "Digital Color Analysis (DCA)", is proposed based on a digital color analyzer instead of the conventional optical methodology, "Spectrophotometry", The digital color analyzer is a hand-held-size instrument for measuring "colors", and it can transform the color information into numerical values, color library data, etc., that can be treated as analytical information, DCA gives us a more informative analytical method than spectrophotometry by treating colors as digital information. In addition, DCA can also simulate the optimum color variations for optimization of the visual sensor with computer assistance. By utilizing colors as digital information, colorimetric analysis that has been used for only semiquantitative analysis can serve as an accurate determination method. On the basis of DCA, we developed a plasticized PVC film optode and a paper optode for Li+ determination in saliva. After the optimization of color variation and the detection range for the Li+ measurements, the optode membrane gives colorless gray in the Li+ therapeutic range (at 10(-3) M) in saliva. Consequently, whether or not the optimum therapeutic Li+ concentration is maintained can be easily evaluated with these optodes, Especially, the sensing paper optode can be easily handled within a short measurement time (similar to 80 s) which is suitable for home use, Using the digital color-analyzer with Q(x)Q(y) coordinates, a linear relation calibration curve can be obtained over the range from 10(-5) to 10(-1) M Li+, in which the analyzer can detect a concentration difference of similar to 0.1 mM Li+. For the near future, an accurate and simple analysis is needed for a health check at home that does not require going to a hospital. The optode based on DCA has great potential for this analytical purpose.
引用
收藏
页码:465 / 474
页数:10
相关论文
共 30 条
[1]   EVALUATION OF COLOR CHANGES OF SULFAMPHTHALEIN INDICATORS - SYNTHESIS, PURIFICATION AND CHARACTERIZATION OF PHENOLSULFAMPHTHALEIN AND ORTHO-CRESOLSULFAMPHTHALEIN [J].
BHUCHAR, VM ;
AGRAWAL, AK .
ANALYST, 1982, 107 (1281) :1439-1450
[2]   EVALUATION OF COLOR CHANGES OF INDICATORS - SPECIFIC COLOR DISCRIMINATION OF PHTHALEIN AND SULFONEPHTHALEIN INDICATORS [J].
BHUCHAR, VM ;
KUKREJA, VP ;
DAS, SR .
ANALYTICAL CHEMISTRY, 1971, 43 (13) :1847-&
[3]  
BODMAN V, 1992, Clinical Chemistry, V38, P1049
[4]   COLOR CHANGES IN SCREENED INDICATORS [J].
BOSCH, E ;
CASASSAS, E ;
IZQUIERDO, A ;
ROSES, M .
ANALYTICAL CHEMISTRY, 1984, 56 (08) :1422-1428
[5]   COMPARATIVE-STUDY OF METALLOCHROMIC INDICATORS FOR MAGNESIUM [J].
CACHO, J ;
LOPEZMOLINERO, A ;
CASTELLS, JE .
ANALYST, 1987, 112 (12) :1723-1729
[6]   EVALUATION OF COLOR CHANGES OF INDICATORS [J].
CACHO, J ;
NERIN, C ;
RUBERTE, L ;
RIVAS, E .
ANALYTICAL CHEMISTRY, 1982, 54 (08) :1446-1449
[7]  
CALATAYUD JM, 1985, ANALUSIS, V13, P87
[8]   SCREENED INDICATORS FOR THE DIRECT CHELOMETRIC TITRATION OF LEAD(II) [J].
CALATAYUD, JM ;
MARTI, MCP ;
VIVES, SS .
ANALYST, 1985, 110 (07) :837-839
[9]  
CURME HG, 1978, CLIN CHEM, V24, P1335
[10]   COLOR SPECIFICATION OF PYRIDINE-2-ALDEHYDE AND 6-METHYLPYRIDINE-2-ALDEHYDE PARA-NITROPHENYLHYDRAZONES AS INDICATORS FOR PH DETERMINATION [J].
FERNANDEZ, AMC ;
CHOZAS, MG .
TALANTA, 1987, 34 (07) :673-676