Transient thermography for structural investigation of concrete and composites in the near surface region

被引:47
作者
Maierhofer, C [1 ]
Brink, A [1 ]
Röllig, M [1 ]
Wiggenhauser, H [1 ]
机构
[1] Fed Inst Mat Res & Testing, BAM, Div 4 4, D-12205 Berlin, Germany
关键词
impulse thermography; non-destructive testing; quantitative analysis; concrete; composites; civil engineering; simulation; finite differences;
D O I
10.1016/S1350-4495(02)00151-2
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The cooling down process of building structures after heating up with an external radiation source was analysed to detect voids inside and below the surface of a concrete test specimen containing voids with different sizes at various depth or covered with carbon fibre reinforcing laminates. These experimental investigations were compared to the results of simulations performed with a finite difference program. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:271 / 278
页数:8
相关论文
共 13 条
[1]  
Busse G., 1992, PROGR PHOTOTHERMAL P, P205
[2]  
CHOWN G, 1983, CANADIAN BUILDING DI
[3]  
DANESI S, 1998, P INT SOC OPT ENG OR, P266
[4]  
Maldague XPV, 1993, NONDESTRUCTIVE EVALU
[5]  
PETTERSON B, 1980, SWEDISH COUNCIL BUIL, P227
[6]  
VAVILOV V, 1994, RES NONDESTRUCT EVAL, V6, P1, DOI 10.1080/09349849409409677
[7]  
Vavilov V, 1997, RES NONDESTRUCT EVAL, V9, P181
[8]  
WEISE F, 1995, P INT S NOND TEST CI, V1, P867
[9]  
ZENZINGER G, 1998, THERMOGRAIFE NEUE MO, P58
[10]  
[No title captured]