Model-based estimation of an anaerobic reductive dechlorination process via an attenuated total reflection-Fourier transform infrared sensor

被引:1
作者
Acha, V
Meurens, M
Naveau, H
Dochain, D
Bastin, G
Agathos, SN
机构
[1] Catholic Univ Louvain, Bioengn Unit, B-1348 Louvain, Belgium
[2] Catholic Univ Louvain, Unit Nutr Biochem, B-1348 Louvain, Belgium
[3] Catholic Univ Louvain, CESAME, B-1348 Louvain, Belgium
关键词
anaerobic dechlorinating bioreactor; aqueous effluents; ATR-FTIR; optical sensor; chlorinated aliphatic hydrocarbons; model-based control; parameter estimation; software sensor;
D O I
10.2166/wst.1999.0379
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Model-based software sensors were built for the estimation of the process variables: cosubstrate, mineral chloride ion, biomass and acetic acid from an anaerobic reductive dechlorination process in a fixed-bed bioreactor, without any the knowledge of the bioprocess kinetics. The estimations were accomplished based only on measurements of chlorinated compounds, obtained by gas chromatography and on-line by an attenuated total reflection-Fourier transform infrared (ATR-FTIR) sensor. In addition, the bioreaction rate of this process was estimated by an observer-based estimator, and validated indirectly by the toxic compound analytical data. (C) 1999 Published by Elsevier Science Ltd on behalf of the IAWQ. All rights reserved.
引用
收藏
页码:33 / 40
页数:8
相关论文
共 23 条
[1]   Detoxification of a mixture of aliphatic chlorinated hydrocarbons in a fixed-bed bioreactor: Continuous on-line monitoring via an attenuated total reflection-Fourier transform infrared sensor [J].
Acha, V ;
Meurens, M ;
Naveau, H ;
Agathos, SN .
WATER SCIENCE AND TECHNOLOGY, 1999, 40 (08) :41-47
[2]  
Acha V, 1998, FIRST INTERNATIONAL CONFERENCE ON REMEDIATION OF CHLORINATED AND RECALCITRANT COMPOUNDS, VOL 4, P135
[3]   Extractive sampling methods to improve the sensitivity of FTIR spectroscopy in analysis of aqueous liquids [J].
Acha, V ;
Naveau, H ;
Meurens, M .
ANALUSIS, 1998, 26 (04) :157-163
[4]   Practical issues in designing estimators under realistic model and sensor errors [J].
Agarwal, M .
CONTROL ENGINEERING PRACTICE, 1998, 6 (02) :197-208
[5]   New boundary conditions and adaptive control of fixed-bed bioreactors [J].
Babary, JP ;
Julien, S ;
Nihtilä, MT ;
Czeczot, J ;
Metzger, M .
CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 1999, 38 (01) :35-44
[6]  
Bastin G., 1990, On-line Estimation and Adaptive Control of Bioreactors
[7]   An environmental process control laboratory: At the interface between instrumentation and model development [J].
Beck, MB ;
Watts, JB ;
Winkler, S .
WATER SCIENCE AND TECHNOLOGY, 1998, 37 (12) :353-362
[8]   HIGH-RATE CONTINUOUS BIODEGRADATION OF CONCENTRATED CHLORINATED ALIPHATICS BY A DURABLE ENRICHMENT OF METHANOGENIC ORIGIN UNDER CARRIER-DEPENDENT CONDITIONS [J].
BOUCQUEY, JB ;
RENARD, P ;
AMERLYNCK, P ;
MODESTO, P ;
AGATHOS, SN ;
NAVEAU, H ;
NYNS, EJ .
BIOTECHNOLOGY AND BIOENGINEERING, 1995, 47 (03) :298-307
[9]   Software sensors in bioprocess engineering [J].
Cheruy, A .
JOURNAL OF BIOTECHNOLOGY, 1997, 52 (03) :193-199
[10]  
Deming SN., 1993, EXPT DESIGN CHEMOMET, DOI DOI 10.1016/j.plaphy.2010.08.016