Continuous intra-arterial blood-gas monitoring in infants and children with cyanotic heart disease

被引:9
作者
Hatherill, M
Tibby, SM
Durward, A
Rajah, V
Murdoch, IA
机构
[1] Paediatric Intensive Care Unit, Guy's Hospital, London SE1 9RT, St Thomas' Street
关键词
hypoxaemia; heart; congenital defects; infants; children; monitoring; blood gases; equipment; gas analysers;
D O I
10.1093/bja/79.5.665
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
We have evaluated the accuracy and reliability of the Paratrend 7 continuous blood-gas analyser in infants and small children under conditions of severe hypoxaemia admitted to the paediatric intensive care unit in the perioperative period with cyanotic congenital heart disease. PO2, PCO2 and pH (hydrogen ion concentration) were measured continuously via a femoral arterial sensor and compared with 100 simultaneous paired arterial blood-gas measurements. Data were analysed by Bland-Altman analysis for bias and precision. Sensors were placed in 10 children of median age 5.43 (range 0.03-45) months, median weight 3.74 (2.79-15.4) kg and remained in place for up to 27 h after operation. PO2 values were 2.5-8.2 kPa (median 5.3 kPa). Co-oximeter saturation ranged from 37.1% to 90.6% (median 75.8%). Bias and precision values were 0.04/0.87 kPa for PO2, -0.44/0.74 kPa for PCO2 and -2.61/6.98 nmol litre(-1) for hydrogen ion concentration (i.e. 0.02/0.06 for pH). We conclude that perioperative continuous arterial gas monitoring is clinically accurate under conditions of severe hypoxaemia in small infants and children with cyanotic congenital heart disease.
引用
收藏
页码:665 / 667
页数:3
相关论文
共 8 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]   NONINVASIVE PULSE OXIMETRY IN CHILDREN WITH CYANOTIC CONGENITAL HEART-DISEASE [J].
BOXER, RA ;
GOTTESFELD, I ;
SINGH, S ;
LACORTE, MA ;
PARNELL, VA ;
WALKER, P .
CRITICAL CARE MEDICINE, 1987, 15 (11) :1062-1064
[3]  
COULE LW, 1996, INTENS CARE MED, V22, pS363
[4]  
Schmitt H J, 1993, J Cardiothorac Vasc Anesth, V7, P61, DOI 10.1016/1053-0770(93)90120-A
[5]   A MULTIPARAMETER SENSOR FOR CONTINUOUS INTRAARTERIAL BLOOD-GAS MONITORING - A PROSPECTIVE EVALUATION [J].
VENKATESH, B ;
BROCK, THC ;
HENDRY, SP .
CRITICAL CARE MEDICINE, 1994, 22 (04) :588-594
[6]   Continuous arterial gas monitoring: Initial experience with the Paratrend 7 in children [J].
Weiss, IK ;
Fink, S ;
Edmunds, S ;
Harrison, R ;
Donnelly, K .
INTENSIVE CARE MEDICINE, 1996, 22 (12) :1414-1417
[7]  
WEISS IK, 1997, CRITICAL CARE MED, V25, pA55
[8]   INITIAL EVALUATION OF A NEW INTRAARTERIAL BLOOD-GAS SYSTEM IN HUMANS [J].
ZIMMERMAN, JL ;
DELLINGER, RP .
CRITICAL CARE MEDICINE, 1993, 21 (04) :495-500