Microchip capillary electrophoresis with a boron-doped diamond electrochemical detector for analysis of aromatic amines

被引:50
作者
Shin, DC
Tryk, DA
Fujishima, A
Muck, A
Chen, G
Wang, J
机构
[1] KAST, Takatsu Ku, Kawasaki, Kanagawa 2130012, Japan
[2] Univ Tokyo, Sch Engn, Dept Appl Chem, Tokyo, Japan
[3] New Mexico State Univ, Dept Chem & Biochem, Las Cruces, NM USA
关键词
amperometric detection; aromatic amines; boron-doped diamond electrode; microchip capillary electrophoresis miniaturization;
D O I
10.1002/elps.200305965
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The attractive features of a boron-doped diamond (BDD) thin-film detector for microchip capillary electrophoretic (CE) separations of dye-related amino-substituted aromatic compounds are described. The diamond electrode was employed in the end-column amperometric detection of 4-aminophenol (4-AP), 1,2-phenylenediamine (1,2-PDA), 2-aminonaphthalene (2-AN), 2-chloroaniline (2-CA), and o-aminobenzoic acid (o-ABA), and its attractive behavior was compared to commonly used screen-printed carbon and glassy-carbon electrodes. These conventional electrode materials exhibit a significant degree of passivation and low sensitivity to the above-mentioned environmental pollutants. The diamond-based electrochemical detection system displayed a favorable analytical performance, including lower noise levels, higher peak resolution with enhanced sensitivity, and improved resistance against electrode passivation. Factors influencing the on-chip analysis were assessed and optimized. The diamond detector displayed detection limits of 2.0 and 1.3 mum for 4-AP and 2-AN, respectively, and a wide linear response for these compounds over the 2-50 mum range. The enhanced stability was demonstrated by relative standard deviation (RSD) values of 1.4% and 4.7% for 100 mum 1,2-PDA and 200 mum 2-CA, respectively, for repetitive detections (n = 7). Besides, the simultaneously observed current decrease was 2.4 and 9.1% for 1,2-PDA and 2-CA, respectively (compared to 21.8 and 41.0% at the screen-printed carbon electrode and 28.3 and 34.1% at the glassy carbon electrode, respectively). The favorable properties of the diamond electrode indicate great promise for environmental applications in CE and other microchip devices.
引用
收藏
页码:3017 / 3023
页数:7
相关论文
共 43 条
[1]   Determination of aromatic amines in water samples by capillary electrophoresis with electrochemical and fluorescence detection [J].
Asthana, A ;
Bose, D ;
Durgbanshi, A ;
Sanghi, SK ;
Kok, WT .
JOURNAL OF CHROMATOGRAPHY A, 2000, 895 (1-2) :197-203
[2]  
Baldwin RP, 2000, ELECTROPHORESIS, V21, P4017, DOI 10.1002/1522-2683(200012)21:18<4017::AID-ELPS4017>3.3.CO
[3]  
2-X
[4]  
Dolník V, 2000, ELECTROPHORESIS, V21, P41, DOI 10.1002/(SICI)1522-2683(20000101)21:1<41::AID-ELPS41>3.0.CO
[5]  
2-7
[6]  
FRANK AP, 1967, IND HYGIENE TOXICOLO, V2
[7]  
Gerhartz W, 1985, ULLMANNS ENCY IND A, V2A
[8]   MICROMACHINING A MINIATURIZED CAPILLARY ELECTROPHORESIS-BASED CHEMICAL-ANALYSIS SYSTEM ON A CHIP [J].
HARRISON, DJ ;
FLURI, K ;
SEILER, K ;
FAN, ZH ;
EFFENHAUSER, CS ;
MANZ, A .
SCIENCE, 1993, 261 (5123) :895-897
[9]  
Huang XJ, 1999, ELECTROANAL, V11, P969, DOI 10.1002/(SICI)1521-4109(199909)11:13<969::AID-ELAN969>3.0.CO
[10]  
2-K