Cost-effectiveness of the implantable cardioverter-defibrillator versus antiarrhythmic drugs in survivors of serious ventricular tachyarrhythmias - Results of the Antiarrhythmics Versus Implantable Defibrillators (AVID) economic analysis substudy

被引:85
作者
Larsen, G
Hallstrom, A
McAnulty, J
Pinski, S
Olarte, A
Sullivan, S
Brodsky, M
Powell, J
Marchant, C
Jennings, C
Akiyama, T
机构
[1] Portland VA Med Ctr, Cardiol Sect, Portland, OR USA
[2] AVID Clin Trial Ctr, Seattle, WA USA
[3] Univ Washington, Seattle, WA 98195 USA
[4] Oregon Hlth Sci Univ, Div Cardiol, Portland, OR 97201 USA
[5] Rush Presbyterian St Lukes Med Ctr, Cardiol Sect, Rush Med Coll, Chicago, IL 60612 USA
[6] Univ Washington, Dept Pharm, Seattle, WA 98195 USA
[7] Univ Washington, Dept Hlth Serv, Seattle, WA 98195 USA
[8] Univ Calif Irvine, Dept Cardiol, Irvine, CA USA
[9] NHLBI, NIH, Bethesda, MD 20892 USA
[10] Univ Rochester, Dept Cardiol, Rochester, NY USA
关键词
cost-benefit analysis; heart arrest; antiarrhythmia agents; defibrillation; tachyarrhythmias;
D O I
10.1161/01.CIR.0000015504.57641.D0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-The implantable cardioverter-defibrillator (ICD) is an effective but expensive device. We used prospectively collected data from a large randomized clinical trial of secondary prevention of life-threatening ventricular arrhythmias to determine the cost-effectiveness of the ICD compared with antiarrhythmic drug (AAD) therapy, largely with amiodarone. Methods and Results-Charges for initial and repeat hospitalizations, emergency room, and day surgery stays and the costs of antiarrhythmic drugs were collected on 1008 patients. Detailed records of all other medical encounters and expenses were collected on a subgroup of 237 patients. Regression models were then created to attribute these expenses to the rest of the patients. Charges were converted to 1997 costs using standard methods. Costs and life years were discounted at 3% per year. Three-year survival data from the Antiarrhythmics Versus Implantable Defibrillators trail were used to calculate the base-case cost-effectiveness (C/E) ratio. Six-year, twenty-year, and lifetime C/E ratios were also estimated. At 3 years. total costs were $71 421 for a patient taking AADs and $85 522 for a patient using an ICD, and the ICD provided a 0.21-year survival benefit over AAD treatment. The base-case C/E ratio was thus $66 677 per year of life saved by the ICD compared with AAD therapy (95% Cl. $30 761 to $154 768). Six- and 20-year C/E ratios remained stable between $68 000 and $80 000 per year of life saved. Conclusions-The ICD is moderately cost-effective for secondary prevention of life-threatening ventricular arrhythmias, as judged from prospectively collected data in a randomized clinical trial.
引用
收藏
页码:2049 / 2057
页数:9
相关论文
共 16 条
  • [1] A randomized study of the prevention of sudden death in patients with coronary artery disease
    Buxton, AE
    Lee, KL
    Fisher, JD
    Josephson, ME
    Prystowsky, EN
    Hafley, G
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1999, 341 (25) : 1882 - 1890
  • [2] Canadian implantable defibrillator study (CIDS) - A randomized trial of the implantable cardioverter defibrillator against amiodarone
    Connolly, SJ
    Gent, M
    Roberts, RS
    Dorian, P
    Roy, D
    Sheldon, RS
    Mitchell, LB
    Green, MS
    Klein, GJ
    O'Brien, B
    [J]. CIRCULATION, 2000, 101 (11) : 1297 - 1302
  • [3] Meta-analysis of the implantable cardioverter defibrillator secondary prevention trials
    Connolly, SJ
    Hallstrom, AP
    Cappato, R
    Schron, EB
    Kuck, KH
    Zipes, DP
    Greene, HL
    Boczor, S
    Domanski, M
    Follmann, D
    Gent, M
    Roberts, RS
    [J]. EUROPEAN HEART JOURNAL, 2000, 21 (24) : 2071 - 2078
  • [4] Relative effectiveness of the implantable cardioverter-defibrillator and antiarrhythmic drugs in patients with varying degrees of left ventricular dysfunction who have survived malignant ventricular arrhythmias
    Domanski, MJ
    Sakseena, S
    Epstein, AE
    Hallstrom, AP
    Brodsky, MA
    Kim, S
    Lancaster, S
    Schron, E
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 34 (04) : 1090 - 1095
  • [5] Efron B., 1982, SOC IND APPL MATH CB, V38, DOI [10.1137/1.9781611970319, DOI 10.1137/1.9781611970319]
  • [6] Gold MR, 1996, COST EFFECTIVENESS H
  • [7] AN ANALYSIS OF THE COST-EFFECTIVENESS OF THE IMPLANTABLE DEFIBRILLATOR
    KUPPERMANN, M
    LUCE, BR
    MCGOVERN, B
    PODRID, PJ
    BIGGER, JT
    RUSKIN, JN
    [J]. CIRCULATION, 1990, 81 (01) : 91 - 100
  • [8] COST-EFFECTIVENESS OF THE IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR - EFFECT OF IMPROVED BATTERY LIFE AND COMPARISON WITH AMIODARONE THERAPY
    LARSEN, GC
    MANOLIS, AS
    SONNENBERG, FA
    BESHANSKY, JR
    ESTES, NAM
    PAUKER, SG
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 19 (06) : 1323 - 1334
  • [9] Prehospital discharge defibrillation testing in ICD recipients: A prospective study based on cost analysis
    Lurie, KG
    Iskos, D
    Fetter, J
    Peterson, CA
    Collins, JM
    Shultz, JJ
    Fahy, GJ
    Sakaguchi, S
    Benditt, DG
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1999, 22 (01): : 192 - 196
  • [10] Fundamentals of economic analysis
    Mark, DB
    Simons, TA
    [J]. AMERICAN HEART JOURNAL, 1999, 137 (05) : S38 - S40