Pitch estimation by early-deafened subjects using a multiple-electrode cochlear implant

被引:12
作者
Busby, PA [1 ]
Clark, GM [1 ]
机构
[1] Univ Melbourne, Dept Otolaryngol, Parkville, Vic 3052, Australia
关键词
D O I
10.1121/1.428353
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Numerical estimates of pitch for stimulation of electrodes along the 22-electrode array of the Cochlear Limited cochlear implant were obtained from 18 subjects who became deaf very early in life. Examined were the relationships between subject differences in pitch estimation, subject variables related to auditory deprivation and experience, and speech-perception scores for closed-set monosyllabic words and open-set Bamford-Kowal-Bench (BKB) sentences. Reliability in the estimation procedure was examined by comparing subject performance in pitch estimation with that for loudness estimation for current levels between hearing threshold and comfortable listening level. For 56% of subjects, a tonotopic order of pitch percepts for electrodes on the array was found; A deviant but reliable order of pitch percepts was found for 22% of subjects, and essentially no pitch order was found for the remaining 22% of subjects. Subject differences in pitch estimation were significantly related to the duration of auditory deprivation prior to implantation, with the poorest performance for subjects who had a longer duration of deafness and a later age at implantation. Subjects with no tonotopic order of pitch percepts had the lowest scores for the BKB sentence test, but there were no differences across subjects for monosyllabic words. Performance in pitch estimation for electrodes did not appear to be related to performance in the estimation procedure, as all subjects were successful in loudness estimation for current level. (C) 2000 Acoustical Society of America. [S0001-4966(99)04312-X].
引用
收藏
页码:547 / 558
页数:12
相关论文
共 48 条
[1]  
Bench R. J., 1979, Speech-hearing tests and the spoken language of hearing-impaired children
[2]   CURRENT DISTRIBUTIONS IN COCHLEAR STIMULATION [J].
BLACK, RC ;
CLARK, GM ;
TONG, YC ;
PATRICK, JF .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1983, 405 (JUN) :137-145
[3]   PITCH PERCEPTION FOR DIFFERENT MODES OF STIMULATION USING THE COCHLEAR MULTIPLE-ELECTRODE PROSTHESIS [J].
BUSBY, PA ;
WHITFORD, LA ;
BLAMEY, PJ ;
RICHARDSON, LM ;
CLARK, GM .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1994, 95 (05) :2658-2669
[4]  
Busby PA, 1996, AUDIOLOGY, V35, P8
[5]   ELECTRODE POSITION, REPETITION RATE, AND SPEECH-PERCEPTION BY EARLY-DEAFENED AND LATE-DEAFENED COCHLEAR IMPLANT PATIENTS [J].
BUSBY, PA ;
TONG, YC ;
CLARK, GM .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1993, 93 (02) :1058-1067
[6]   PREFERRED METHOD FOR CLINICAL DETERMINATION OF PURE-TONE THRESHOLDS [J].
CARHART, R ;
JERGER, JF .
JOURNAL OF SPEECH AND HEARING DISORDERS, 1959, 24 (04) :330-345
[7]  
CLARK GM, 1987, ARCH OTOLARYNGOL, V113, P825
[8]  
CLARK GM, 1988, ACTA OTOLARYNGOL S, V488, P1
[9]  
Cohen L T, 1996, Audiol Neurootol, V1, P265
[10]  
Cohen L T, 1996, Audiol Neurootol, V1, P278