Increase in iris-lens contact after laser iridotomy for pupillary block angle closure

被引:73
作者
Caronia, RM
Liebmann, JM
Stegman, Z
Sokol, J
Ritch, R
机构
[1] NEW YORK EYE & EAR INFIRM,DEPT OPHTHALMOL,GLAUCOMA SERV,NEW YORK,NY 10003
[2] NEW YORK MED COLL,VALHALLA,NY 10595
关键词
D O I
10.1016/S0002-9394(14)71963-4
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To quantitate changes in anterior ocular segment anatomy after laser iridotomy for pupillary block angle closure. METHODS: We prospectively performed ultrasound biomicroscopy and A-scan biometry in 13 eyes of 13 consecutive untreated patients with relative pupillary block and appositional angle closure, without peripheral anterior synechiae on indentation gonioscopy. A radial, perpendicular image in the horizontal temporal meridian was obtained with ultrasound biomicroscopy before and one week after laser iridotomy in each eye. RESULTS: Mean age of the 13 patients was 69.3 +/- 1.8 (S.E.) years, mean refractive error was +1.37 +/- 0.39 diopters, and mean axial length was 22.54 +/- 0.20 mm. In 13 eyes, before and after laser iridotomy measurements of angle-opening distance (0.11 +/- 0.02 vs. 0.18 +/- 0.02 mm) (P = .0004; paired t test), angle aperture (8.3 +/- 1.3 vs 18.6 +/- 2.8 degrees) (P = .0003) and iris-lens contact distance (0.58 +/- 0.06 vs 1.18 +/- 0.14 mm) (P = .0003) were greater postoperatively, but anterior chamber depth was unchanged (P = .7). CONCLUSIONS: Flattening of the iris after laser iridotomy for pupillary block causes an increase in iris-lens contact. The change in angle configuration after iridotomy results more from an alteration in aqueous pressure gradients across the iris rather than from posterior lens movement.
引用
收藏
页码:53 / 57
页数:5
相关论文
共 11 条
[1]   THE PHYSIOLOGICAL-CHARACTERISTICS OF RELATIVE PUPILLARY BLOCK [J].
ANDERSON, DR ;
JIN, JC ;
WRIGHT, MM .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1991, 111 (03) :344-350
[2]  
JACOBS IH, 1980, AM J OPHTHALMOL, V88, P865
[3]   THE EFFECT OF IRIDOTOMY ON IRIS CONTOUR [J].
JIN, JC ;
ANDERSON, DR .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1990, 110 (03) :260-263
[4]  
LEE DA, 1984, ARCH OPHTHALMOL-CHIC, V102, P46
[5]  
PAVLIN CJ, 1990, OPHTHALMOLOGY, V97, P244
[6]   ULTRASOUND BIOMICROSCOPY OF ANTERIOR SEGMENT STRUCTURES IN NORMAL AND GLAUCOMATOUS EYES [J].
PAVLIN, CJ ;
HARASIEWICZ, K ;
FOSTER, FS .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1992, 113 (04) :381-389
[7]  
PAVLIN CJ, 1991, OPHTHALMOLOGY, V98, P287
[8]  
PAVLIN CJ, 1994, CAN J OPHTHALMOL, V29, P187
[9]  
POTASH SD, 1994, OPHTHALMOLOGY, V101, P332
[10]  
RICHARDS DW, 1988, INVEST OPHTH VIS SCI, V29, P1826