Low-temperature CO oxidation over a Pt/Al2O3 monolith catalyst investigated by step-response experiments and simulations

被引:33
作者
Carlsson, PA [1 ]
Skoglundh, M
Thormählen, P
Andersson, B
机构
[1] Chalmers, Competence Ctr Catalysis, SE-41296 Gothenburg, Sweden
[2] Chalmers, Dept Chem Engn & Environm Sci, SE-41296 Gothenburg, Sweden
[3] Chalmers, Dept Appl Phys, SE-41296 Gothenburg, Sweden
[4] Chalmers, Dept Mat & Surface Chem, SE-41296 Gothenburg, Sweden
关键词
cold-start; self-poisoning; low-temperature activity; step-response experiment; CO oxidation; catalytic ignition; catalytic extinction; mean-field modelling; simulations; Pt/Al2O3;
D O I
10.1023/B:TOCA.0000029778.29111.fe
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
The ignition-extinction processes for CO oxidation over a Pt/Al2O3 monolith catalyst have been studied by flow-reactor experiments and simulations. The study was performed by stepwise changes of the inlet O-2 concentration ranging 0-20 vol% while the CO concentration and the inlet gas temperature were kept constant at 1.0 vol% and 423 K, respectively. Several features observed experimentally are qualitatively simulated with our model: (i) the ignition of the CO oxidation demands 8.0 vol% O-2\ (ii) corresponding to a catalyst ignition temperature of 433 K (due to the exothermicity of the reaction) and (iii) occurs in the rear part of the monolith where (iv) a local reaction zone is formed which (v) moves towards the reactor inlet as a function of time on stream. Additionally, the simulations show first order kinetic phase transitions, i.e. rapid adsorbate concentration changes, where the catalyst surface is predominantly CO covered in the low reactive state and almost completely oxygen covered in the high reactive state. For the ignition process the kinetic phase transition occurs after the actual catalytic ignition. However, the extinction process is more difficult to simulate dynamically without changing the model parameters for O-2 adsorption in the low and high reactive state, respectively. The influence of diffusion limitations and the role of formation of a less reactive Pt state under oxidising conditions is discussed.
引用
收藏
页码:375 / 381
页数:7
相关论文
共 21 条
[1]  
BAR M, 1992, J CHEM PHYS, V96, P8595, DOI 10.1063/1.462312
[2]  
Carlson PJ, 2002, TRANSPORT RES REC, P27
[3]   Induced low temperature catalytic ignition by transient changes in the gas composition [J].
Carlsson, PA ;
Skoglundh, M ;
Fridell, E ;
Jobson, E ;
Andersson, B .
CATALYSIS TODAY, 2002, 73 (3-4) :307-313
[4]   Periodic control for improved low-temperature catalytic activity [J].
Carlsson, PA ;
Thormählen, P ;
Skoglundh, M ;
Persson, H ;
Fridell, E ;
Jobson, E ;
Andersson, B .
TOPICS IN CATALYSIS, 2001, 16 (1-4) :343-347
[5]  
DIMITRIOS DN, 2003, CHEM ENG SCI, V58, P179
[6]  
ENGEL T, 1979, ADV CATAL, V28, P1
[7]  
FRANKKAMENETSKI.DA, 1969, DIFFUSION HEAT TRANS, P463
[8]   Automobile exhaust catalysts [J].
Heck, RM ;
Farrauto, RJ .
APPLIED CATALYSIS A-GENERAL, 2001, 221 (1-2) :443-457
[9]   Mass transfer in monolith catalysts - CO oxidation experiments and simulations [J].
Holmgren, A ;
Andersson, B .
CHEMICAL ENGINEERING SCIENCE, 1998, 53 (13) :2285-2298
[10]   CO oxidation bistability diagrams for Pt/CeOx and Pt/SiO2 model catalysts prepared by electron-beam lithography [J].
Johansson, S ;
Österlund, L ;
Kasemo, B .
JOURNAL OF CATALYSIS, 2001, 201 (02) :275-285