Hydroxyapatite-based electrode: A new sensor for phosphate

被引:34
作者
Petrucelli, GC
Kawachi, EY
Kubota, LT
Bertran, CA
机构
[1] Inst. de Química da Unicamp, 13083-970 Campinas, SP
来源
ANALYTICAL COMMUNICATIONS | 1996年 / 33卷 / 07期
关键词
D O I
10.1039/ac9963300227
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Hydroxyapatite, prepared by precipitation from a calcium hydroxide suspension with phosphoric acid at 60 degrees C and a pH of 9, was used to develop a potentiometric sensor for phosphate. The electrodes were made in two ways: firstly, by mixing hydroxyapatite powder with an epoxy polymer and graphite; and secondly, by sealing porous hydroxyapatite sticks to the extremity of a glass tube. The first sensor showed a very small linear range of response (6.0 x 10(-5) to 2.0 x 10(-4) mol l(-1)) to log [phosphate] at pH = 5.0, with a slope of 55 mV decade(-1) of phosphate concentration and a detection limit of 4.0 x 10(-5) mol l(-1). The second showed a higher linear response range from 5.0 x 10(-5) up to 5.0 x 10(-2) mol l(-1), with a slope of 33 mV decade(-1) and a detection limit of 2.5 x 10(-5) mol l(-1), under the same conditions. The response time was about 25 s in the first case and 40 s in the second. The effects of interfering ions were investigated and the K-pot values for Cl-, NO3-, SO42-, ClO4-, acetate and citrate were determined, showing only a small interference with the electrode response. The powder electrode is not stable but the stick has good stability.
引用
收藏
页码:227 / 229
页数:3
相关论文
共 19 条
[1]   MECHANISMS AND STRUCTURE OF THE BOND BETWEEN BONE AND HYDROXYAPATITE CERAMICS [J].
BAGAMBISA, FB ;
JOOS, U ;
SCHILLI, W .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1993, 27 (08) :1047-1055
[2]  
BAILEY PL, 1990, ANAL ION SELECTIVE E, P49
[3]   AMPEROMETRIC ENZYMATIC GLUCOSE ELECTRODE BASED ON AN EPOXY GRAPHITE COMPOSITE [J].
CESPEDES, F ;
MARTINEZFABREGAS, E ;
BARTROLI, J ;
ALEGRET, S .
ANALYTICA CHIMICA ACTA, 1993, 273 (1-2) :409-417
[4]   POTENTIOMETRIC PHOSPHATE SELECTIVE ELECTRODE BASED ON A MULTIDENDATE TIN(IV) CARRIER [J].
CHANIOTAKIS, NA ;
JURKSCHAT, K ;
RUHLEMANN, A .
ANALYTICA CHIMICA ACTA, 1993, 282 (02) :345-352
[5]   A NEW SENSOR FOR PERCHLORATE ION [J].
FERNANDES, JR ;
KUBOTA, LT ;
GUSHIKEM, Y ;
NETO, GD .
ANALYTICAL LETTERS, 1993, 26 (12) :2555-2563
[6]   SELECTIVITY OF MEMBRANE ELECTRODES BASED ON DERIVATIVES OF DIBENZYLTIN DICHLORIDE [J].
GLAZIER, SA ;
ARNOLD, MA .
ANALYTICAL CHEMISTRY, 1991, 63 (08) :754-759
[7]   HYDROXYAPATITE AS A LIQUID-CHROMATOGRAPHIC PACKING [J].
KAWASAKI, T .
JOURNAL OF CHROMATOGRAPHY, 1991, 544 (1-2) :147-184
[8]  
LIMA JLF, 1983, 4 REUN NAC EL BRAG P
[9]   POTENTIOMETRIC STUDY USING CHEMICALLY-MODIFIED SILICA-GEL WITH PYRIDINIUM AS MEMBRANE FOR CIO4(-) IONS [J].
LORENCETTI, LL ;
GUSHIKEM, Y ;
KUBOTA, LT ;
NETO, GD ;
FERNANDES, JR .
MIKROCHIMICA ACTA, 1995, 117 (3-4) :239-244
[10]   CALCIUM-SENSITIVE ELECTRODE BASED ON A LIQUID ION EXCHANGER IN A POLY(VINYL-CHLORIDE) MATRIX [J].
MOODY, GJ ;
OKE, RB ;
THOMAS, JDR .
ANALYST, 1970, 95 (1136) :910-&