Determination of heterogeneous electron transfer rate constants at interdigitated nanoband electrodes fabricated by an optical mix-and-match process

被引:19
作者
Javier del Campo, Francisco [1 ]
Abad, Llibertat [1 ]
Illa, Xavi [1 ,2 ]
Prats-Alfonso, Elisabet [1 ,2 ]
Borrise, Xavier [3 ]
Maria Cirera, Josep [1 ]
Bai, Huei-Yu [4 ]
Tsai, Yu-Chen [4 ]
机构
[1] Esfera UAB, IMB CNM CSIC, Inst Microelect Barcelona, Barcelona 08193, Spain
[2] Networking Ctr Bioengn Biomat & Nanomed, CIBER BBN, Zaragoza, Spain
[3] Inst Catala Nanociencia & Nanotecnol ICN2, Barcelona 08193, Spain
[4] Natl Chung Hsing Univ, Dept Chem Engn, Taichung 402, Taiwan
关键词
Microband electrodes; Redox cycling; Generator-collector experiments; Electrochemical simulation; Electrode kinetics; Microfabrication; LINEAR SWEEP VOLTAMMETRY; ARRAY ELECTRODES; MASS-TRANSPORT; STEADY-STATE; ELECTROCHEMICAL DETECTION; MICRODISK ELECTRODES; MICROBAND ELECTRODES; SIMULATION; MICROELECTRODES; NANOELECTRODES;
D O I
10.1016/j.snb.2013.12.016
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Interdigitated microband electrodes are important electroanalytical tools, and have been used in the construction of advanced sensing and biosensing devices for a long time. Nanoband-based systems, on the other hand, are more difficult to come by, as their fabrication involves the use of costly and scarce e-beam lithography resources. In this work we present the fabrication of interdigitated nanobands down to 400 nm using optical techniques exclusively. The process combines a step-and-repeat process to define Cr-Au nano- and microbands, and a standard lithography to pattern the active areas and contacts through an SU-8 passivation layer. This work presents the physical and electrochemical characterization of these devices, and our results also show that generator-collector experiments at these nanometric devices can be used in conventional electroanalytical applications, but also to measure electrode kinetics. While electrode kinetics does not affect collection efficiency to a great extent, the fast mass transport rates achieved at these devices makes the voltammetric current critically dependent on electron transfer rates. (C) 2013 Elsevier B. V. All rights reserved.
引用
收藏
页码:86 / 95
页数:10
相关论文
共 62 条
  • [1] Design and fabrication of a COP-based microfluidic chip: Chronoamperometric detection of Troponin T
    Abad, Llibertat
    Javier del Campo, Francisco
    Xavier Munoz, Francesc
    Fernandez, Luis J.
    Calavia, Daniel
    Colom, Gloria
    Salvador, Juan P.
    Pilar Marco, Maria
    Escamilla-Gomez, Vanessa
    Esteban-Fernandez de Avila, Berta
    Campuzano, Susana
    Pedrero, Maria
    Pingarron, Jose M.
    Godino, Neus
    Gorkin, Robert, III
    Ducree, Jens
    [J]. ELECTROPHORESIS, 2012, 33 (21) : 3187 - 3194
  • [2] Channel microband electrode arrays for mechanistic electrochemistry. Two dimensional voltammetry: Transport-limited currents
    Alden, JA
    Feldman, MA
    Hill, E
    Prieto, F
    Oyama, M
    Coles, BA
    Compton, RG
    Dobson, PJ
    Leigh, PA
    [J]. ANALYTICAL CHEMISTRY, 1998, 70 (09) : 1707 - 1720
  • [3] CHARGE-TRANSFER AT PARTIALLY BLOCKED SURFACES - A MODEL FOR THE CASE OF MICROSCOPIC ACTIVE AND INACTIVE SITES
    AMATORE, C
    SAVEANT, JM
    TESSIER, D
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1983, 147 (1-2) : 39 - 51
  • [4] Mass Transport at Microband Electrodes: Transient, Quasi-Steady-State, and Convective Regimes
    Amatore, Christian
    Pebay, Cecile
    Sella, Catherine
    Thouin, Laurent
    [J]. CHEMPHYSCHEM, 2012, 13 (06) : 1562 - 1568
  • [5] THEORY OF CHRONOAMPEROMETRIC CURVES FOR A SHORT-TIME AT MICROBAND ELECTRODES
    AOKI, K
    TOKUDA, K
    MATSUDA, H
    [J]. DENKI KAGAKU, 1986, 54 (12): : 1010 - 1017
  • [6] QUANTITATIVE-ANALYSIS OF REVERSIBLE DIFFUSION-CONTROLLED CURRENTS OF REDOX SOLUBLE SPECIES AT INTERDIGITATED ARRAY ELECTRODES UNDER STEADY-STATE CONDITIONS
    AOKI, K
    MORITA, M
    NIWA, O
    TABEI, H
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1988, 256 (02): : 269 - 282
  • [7] THEORY OF THE STEADY-STATE CURRENT OF A REDOX COUPLE AT INTERDIGITATED ARRAY ELECTRODES OF WHICH PAIRS ARE INSULATED ELECTRICALLY BY STEPS
    AOKI, K
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1989, 270 (1-2): : 35 - 41
  • [8] LINEAR SWEEP VOLTAMMETRY AT MICROBAND ELECTRODES
    AOKI, K
    TOKUDA, K
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1987, 237 (02): : 163 - 170
  • [9] Gold nanoparticle-based quantitative electrochemical detection of amplified human cytomegalovirus DNA using disposable microband electrodes
    Authier, L
    Grossiord, C
    Brossier, P
    Limoges, B
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (18) : 4450 - 4456
  • [10] DIGITAL-SIMULATION OF THE MEASURED ELECTROCHEMICAL RESPONSE OF REVERSIBLE REDOX COUPLES AT MICROELECTRODE ARRAYS - CONSEQUENCES ARISING FROM CLOSELY SPACED ULTRAMICROELECTRODES
    BARD, AJ
    CRAYSTON, JA
    KITTLESEN, GP
    SHEA, TV
    WRIGHTON, MS
    [J]. ANALYTICAL CHEMISTRY, 1986, 58 (11) : 2321 - 2331