Analysis of the radiometer-reference load system on board the Planck/LFI instrument

被引:7
作者
Cuttaia, F
Valenziano, L
Bersanelli, M
Butler, RC
D'Arcangelo, O
Kettle, D
Levin, S
Mandolesi, N
Mennella, A
Morgante, G
Morigi, G
Roddis, N
Simonetto, A
Terenzi, L
Tomasi, M
Villa, F
机构
[1] CNR, IASF, Sez Bologna, I-40129 Bologna, Italy
[2] Univ Milan, Dipartimento Fis, I-20133 Milan, Italy
[3] CNR, IFP, I-20125 Milan, Italy
[4] Jodrell Bank, Macclesfield SK11 9DL, Cheshire, England
[5] CALTECH, Jet Prop Lab, Pasadena, CA 91109 USA
[6] CNR, IASF, Sez Milano, I-20133 Milan, Italy
关键词
cosmology; cosmic microwave background; satellite; Planck; radiometer; blackbody; finite element method;
D O I
10.1016/j.nima.2003.11.344
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The Low Frequency Instrument aboard the Planck satellite will employ pseudo-correlation radiometers, operating over three broad bands centered at 30, 44, 70GHz. This choice is oriented to maximize the instrumental stability reducing non-white noise effects produced inside the radiometers. The radiometer scheme allows the simultaneous comparison of two input signals, one coming from the telescope and the other coming from a reference blackbody (the "reference load" RL) at a stable temperature near 4 K. In order to minimize non-white noise, typically exhibiting a I If spectrum, the Reference Load temperature must be as close as possible to the sky temperature (about 2.7 K). The accuracy of the measurement is tightly related to the ability of keeping under control and minimizing all systematic effects potentially. perturbing the RL signal, particularly those not easily removable in software during data analysis. A model of the,radiometer and RL system interface, based on the finite elements method, has been developed, together with a detailed thermal modeling, to characterize the physical system and to optimize its performance. The function of the radiometric chain, the modeling and the changes made in the baseline configuration to improve the system performances are described. The impact of systematic effects on the optimized configuration are also quantitatively investigated. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:396 / 401
页数:6
相关论文
共 12 条
[1]  
*EM CUM CORP, 1977, ECCOSORB CR APPL NOT
[2]   FAR INFRARED TRANSMISSION OF DIELECTRICS AT CRYOGENIC AND ROOM TEMPERATURES - GLASS, FLUOROGOLD, ECCOSORB, STYCAST, AND VARIOUS PLASTICS [J].
HALPERN, M ;
GUSH, HP ;
WISHNOW, E ;
DECOSMO, V .
APPLIED OPTICS, 1986, 25 (04) :565-570
[3]   SUBMILLIMETER AND MILLIMETER-WAVE CHARACTERIZATION OF ABSORBING MATERIALS [J].
HEMMATI, H ;
MATHER, JC ;
EICHHORN, WL .
APPLIED OPTICS, 1985, 24 (24) :4489-4492
[4]  
Lamarre JM, 2002, AIP CONF PROC, V616, P213, DOI 10.1063/1.1475631
[5]  
LAMB JW, MISCELLANEOUS DATA M
[6]   The Planck satellite [J].
Mandolesi, N ;
Villa, F ;
Valenziano, L .
NEW RESULTS IN FAR IR AND SUB-MM ASTRONOMY, 2002, 30 (09) :2123-2128
[7]  
Mandolesi N, 2002, AIP CONF PROC, V616, P193, DOI 10.1063/1.1475627
[8]   Calibrator design for the COBE far infrared absolute spectrophotometer (FIRAS) [J].
Mather, JC ;
Fixsen, DJ ;
Shafer, RA ;
Mosier, C ;
Wilkinson, DT .
ASTROPHYSICAL JOURNAL, 1999, 512 (02) :511-520
[9]   A CRYOGENIC BLACKBODY FOR MILLIMETER WAVELENGTHS [J].
PETERSON, JB ;
RICHARDS, PL .
INTERNATIONAL JOURNAL OF INFRARED AND MILLIMETER WAVES, 1984, 5 (12) :1507-1515
[10]   1/f noise and other systematic effects in the Planck-LFI radiometers [J].
Seiffert, M ;
Mennella, A ;
Burigana, C ;
Mandolesi, N ;
Bersanelli, M ;
Meinhold, P ;
Lubin, P .
ASTRONOMY & ASTROPHYSICS, 2002, 391 (03) :1185-1197