Challenges and constraints of using oxygen cathodes in microbial fuel cells

被引:459
作者
Zhao, Feng
Harnisch, Falk
Schroerder, Uwe
Scholz, Fritz
Bogdanoff, Peter
Herrmann, Iris
机构
[1] Ernst Moritz Arndt Univ Greifswald, Inst Chem & Biochem, D-17489 Greifswald, Germany
[2] Hahn Meitner Inst Berlin GmbH, D-14109 Berlin, Germany
关键词
D O I
10.1021/es060332p
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The performance of oxygen reduction catalysts (platinum, pyrolyzed iron(II) phthalocyanine (pyr-FePc) and cobalt tetramethoxyphenylporphyrin (pyr-CoTMPP)) is discussed in light of their application in microbial fuel cells. It is demonstrated that the physical and chemical environment in microbial fuel cells severely affects the thermodynamics and the kinetics of the electrocatalytic oxygen reduction. The neutral pH in combination with low buffer capacities and low ionic concentrations strongly affect the cathode performance and limit the fuel cell power output. Thus, the limiting current density in galvanodyanamic polarization experiments decreases from 1.5 mA cm(-2) to 0.6 mA cm-2 (pH 3.3, E-cathode = 0 V) when the buffer concentration is decreased from 500 to 50 mM. The cathode limitations are superposed by the increasing internal resistance of the MFC that substantially contributes to the decrease of power output. For example, the maximum power output of a model MFC decreased by 35%, from 2.3 to 1.5 mW, whereas the difference between the electrode potentials (Delta E = E-anode-E-cathode) decreased only by 10%. The increase of the catalyst load of pyr-FePc from 0.25 to 2 mg cm-2 increased the cathodic current density from 0.4 to 0.97 mA cm(-2) (pH 7, 50 mM phosphate buffer). The increase of the load of such inexpensive catalyst thus represents a suitable means to improve the cathode performance in microbial fuel cells. Due to the low concentration of protons in MFCs in comparison to relatively high alkali cation levels (ratio c(Na+, K+)/c(H+) = 5 x E5 in pH 7, 50 mM phosphate buffer) the transfer of alkali ions through the proton exchange membrane plays a major role in the charge-balancing ion flux from the anodic into the cathodic compartment. This leads to the formation of pH gradients between the anode and the cathode compartment.
引用
收藏
页码:5193 / 5199
页数:7
相关论文
共 40 条
[1]  
[Anonymous], 2003, ANGEW CHEM, DOI DOI 10.1002/ange.200350918
[2]  
[Anonymous], 2000, HDB CHEM PHYS
[3]   Alternative cathodes based on iron phthalocyanine catalysts for mini- or micro-DMFC working at room temperature [J].
Baranton, S ;
Coutanceau, C ;
Léger, JM ;
Roux, C ;
Capron, P .
ELECTROCHIMICA ACTA, 2005, 51 (03) :517-525
[4]  
Bogdanoff P, 2004, J NEW MAT ELECTR SYS, V7, P85
[5]   Power densities using different cathode catalysts (Pt and CoTMPP) and polymer binders (Nafion and PTFE) in single chamber microbial fuel cells [J].
Cheng, S ;
Liu, H ;
Logan, BE .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2006, 40 (01) :364-369
[6]   Increased performance of single-chamber microbial fuel cells using an improved cathode structure [J].
Cheng, S ;
Liu, H ;
Logan, BE .
ELECTROCHEMISTRY COMMUNICATIONS, 2006, 8 (03) :489-494
[7]   CONDUCTING POLYMER ELECTRODES MODIFIED BY METAL TETRASULFONATED PHTHALOCYANINES - PREPARATION AND ELECTROCATALYTIC BEHAVIOR TOWARDS DIOXYGEN REDUCTION IN ACID-MEDIUM [J].
COUTANCEAU, C ;
ELHOURCH, A ;
CROUIGNEAU, P ;
LEGER, JM ;
LAMY, C .
ELECTROCHIMICA ACTA, 1995, 40 (17) :2739-2748
[8]   Operational parameters affecting the performance of a mediator-less microbial fuel cell [J].
Gil, GC ;
Chang, IS ;
Kim, BH ;
Kim, M ;
Jang, JK ;
Park, HS ;
Kim, HJ .
BIOSENSORS & BIOELECTRONICS, 2003, 18 (04) :327-334
[9]   Heat-treated iron(III) tetramethoxyphenyl porphyrin chloride supported on high-area carbon as an electrocatalyst for oxygen reduction: Part III. Detection of hydrogen-peroxide during oxygen reduction [J].
Gojkovic, SL ;
Gupta, S ;
Savinell, RF .
ELECTROCHIMICA ACTA, 1999, 45 (06) :889-897
[10]   Heat-treated iron(III) tetramethoxyphenyl porphyrin chloride supported on high-area carbon as an electrocatalyst for oxygen reduction - Part II. Kinetics of oxygen reduction [J].
Gojkovic, SL ;
Gupta, S ;
Savinell, RF .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1999, 462 (01) :63-72