Colonoscopy aided by magnetic 3D imaging: assessing the routine use of a stiffening sigmoid overtube to speed up the procedure

被引:16
作者
Bell, GD [1 ]
Rowland, RS
Rutter, M
Abu-Sada, M
Dogramadzi, S
Allen, C
机构
[1] Univ Sunderland, Fac Med Sci, Sunderland SR2 7EE, Durham, England
[2] RMR Syst Ltd, Kirton, Suffolk, England
[3] Univ Newcastle, Dept Elect & Elect Engn, Newcastle Upon Tyne, Tyne & Wear, England
关键词
colonoscopy; stiffening overtube; 3D computerised magnetic imaging; measurement of colonic length;
D O I
10.1007/BF02513355
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
There are not enough trained colonoscopists to cope with the present recommended number of examinations required for diagnostic and surveillance purposes. If colorectal cancer screening is to be introduced, endoscopic examination of the large bowel needs to be easier to learn and significantly quicker to carry out. The 'Bladen system', first described in 1993, is a non-radiological method of visualising the path of the endoscope, using magnetic drive coils under the patient and a chain of sensors along the biopsy channel of the instrument. In 1998, results were published using a novel computer graphics system (the RMR system), in which a much more realistic image of the endoscope could be produced using the stored positional data from the Bladen system. The RMR system has been further refined to allow, for the first rime ever, accurate measurement of the effect of the passage of a colonoscope along the bowel on the lengths of different segments of the large intestine. The results obtained in 232 patients undergoing colonoscopy are analysed. In 77 of the patients, a stiffening overtube is used to splint the sigmoid colon once the endoscope is at or beyond the splenic flexure. The mean time taken to pass the colonoscope across the transverse colon is significantly shorter (p < 0.001) when an overtube is used, despite it resulting in significant lengthening of the transverse colon. The routine use of a stiffening overtube can be expected to reduce the total procedure time by between 10 and 20%.
引用
收藏
页码:605 / 611
页数:7
相关论文
共 16 条
[1]   COLONOSCOPE LENGTH AND PROCEDURE EFFICIENCY [J].
BARTHEL, J ;
HINOJOSA, T ;
SHAH, N .
JOURNAL OF CLINICAL GASTROENTEROLOGY, 1995, 21 (01) :30-32
[2]   Prime ideals and radicals in semigroup-graded rings [J].
Bell, AD ;
Stalder, S ;
Teply, ML .
PROCEEDINGS OF THE EDINBURGH MATHEMATICAL SOCIETY, 1996, 39 :1-25
[3]   NON-RADIOLOGICAL TECHNIQUE FOR 3-DIMENSIONAL IMAGING OF ENDOSCOPES [J].
BLADEN, JS ;
ANDERSON, AP ;
BELL, GD ;
RAMEH, B ;
EVANS, B ;
HEATLEY, DJT .
LANCET, 1993, 341 (8847) :719-722
[4]  
*END SECT COMM BRI, 1987, GUT, V28, P772
[5]  
HUNT RH, 1981, COLONOSCOPY TECHNIQU, P128
[6]  
Khullar S K, 1997, Gastrointest Endosc Clin N Am, V7, P365
[7]   COST-EFFECTIVENESS MODEL FOR COLON-CANCER SCREENING [J].
LIEBERMAN, DA .
GASTROENTEROLOGY, 1995, 109 (06) :1781-1790
[8]   Device for measuring the forces exerted on the shaft of an endoscope during colonoscopy [J].
Mosse, CA ;
Mills, TN ;
Bell, GD ;
Swain, CP .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1998, 36 (02) :186-190
[9]  
*OFF POP CENS SURV, 1991, MORT STAT CAUS 1 DH2, V16
[10]   COMPETENCE AND THE COLONOSCOPIST - A LEARNING-CURVE [J].
PARRY, BR ;
WILLIAMS, SM .
AUSTRALIAN AND NEW ZEALAND JOURNAL OF SURGERY, 1991, 61 (06) :419-422