Simultaneous determination of airborne carbamates in workplace by high performance liquid chromatography with fluorescence detection

被引:69
作者
Li, HP
Li, JH
Li, GC
Jen, JF [1 ]
机构
[1] Natl Chung Hsing Univ, Dept Chem, Taichung 402, Taiwan
[2] Taiwan Agr Chem & Toxic Substances Res Inst, Residure Control Div, COA, Taichung 413, Hsien, Taiwan
关键词
carbamates; pesticides; airborne sampling; XAD-2; derivatization;
D O I
10.1016/j.talanta.2003.11.031
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A high performance liquid chromatography with fluorescence (HPLC-F) detector was examined to simultaneous determination of airborne carbamates in the workplace of manufactory. The OVS-2 air sampling tube filled with glass fiber filter or quartz fiber and combined filter/XAD-2 were evaluated to collect nine commonly used carbamates (Carbofuran, Isoprocarb, Methomyl, Metolcarb, Thiodicarb, Carbaryl, Oxamyl, Methiocarb, and Prpoxur) from the air of manufactory in high humidity country. After being extracted with acetonitrile from sampling tubes, the carbamates were determined by high performance liquid chromatography with fluorescence detection posterior to on-line derivatization. The collection of carbamates and the recovery of extraction from glass wool fiber in several concentration levels, and from quartz filter were evaluated. The storage stability of carbamates was also tested. Results indicated that the HPLC-fluorescence method offers satisfactory resolution and sensitivity in carbamate analysis. With the glass fiber filter and combined filter/XAD-2, the Carbofuran, Isoprocarb, Methomyl, Metolcarb, and Thiodicarb were stable for a 28-day storage test, Carbaryl and Oxamyl for 14 days, and Methiocarb and Prpoxur for 7 days. All of these pesticides were with detection limit of 3 mug m(-3). It is suited for environmental monitoring. The airborne carbamates in different areas of the manufactory were measured. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:547 / 553
页数:7
相关论文
共 19 条
[1]   Determination of carbaryl, carbofuran and methiocarb in cucumbers and strawberries by monoclonal enzyme immunoassays and high-performance liquid chromatography with fluorescence detection -: An analytical comparison [J].
Abad, A ;
Moreno, MJ ;
Pelegrí, R ;
Martínez, MI ;
Sáez, A ;
Gamón, M ;
Montoya, A .
JOURNAL OF CHROMATOGRAPHY A, 1999, 833 (01) :3-12
[2]   Biological monitoring of pesticide exposure: a review of analytical methods [J].
Aprea, C ;
Colosio, C ;
Mammone, T ;
Minoia, C ;
Maroni, M .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 769 (02) :191-219
[3]   Evaluation of analytical methods for determining pesticides in baby food [J].
Chuang, JC ;
Pollard, MA ;
Misita, M ;
Van Emon, JM .
ANALYTICA CHIMICA ACTA, 1999, 399 (1-2) :135-142
[4]   Simplified method for the determination of chlorinated fungicides and insecticides in fruits by gas chromatography [J].
Columé, A ;
Cárdenas, S ;
Gallego, M ;
Valcárcel, M .
JOURNAL OF CHROMATOGRAPHY A, 2000, 882 (1-2) :193-203
[5]   Multiclass/multiresidue method for monitoring widely applied plant protecting agents in air during field dispersion work [J].
Demel, J ;
Buchberger, W ;
Malissa, H .
JOURNAL OF CHROMATOGRAPHY A, 2001, 931 (1-2) :107-117
[6]  
Fillion J, 1995, J AOAC INT, V78, P1252
[7]   Biological monitoring of exposure to pesticides: current issues [J].
He, FS .
TOXICOLOGY LETTERS, 1999, 108 (2-3) :277-283
[8]  
KRAUSE RT, 1980, J ASSOC OFF ANA CHEM, V63, P1114
[9]  
KRAUSE RT, 1985, J ASSOC OFF ANA CHEM, V68, P726
[10]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHODS FOR THE DETERMINATION OF N-METHYLCARBAMATE PESTICIDES IN WATER, SOIL, PLANTS AND AIR [J].
MCGARVEY, BD .
JOURNAL OF CHROMATOGRAPHY, 1993, 642 (1-2) :89-105