Argus:: a new instrument for the measurement of the stratospheric dynamical tracers, N2O and CH4

被引:34
作者
Loewenstein, M [1 ]
Jost, H [1 ]
Grose, J [1 ]
Eilers, J [1 ]
Lynch, D [1 ]
Jensen, S [1 ]
Marmie, J [1 ]
机构
[1] NASA, Ames Res Ctr, Moffett Field, CA 94035 USA
关键词
stratosphere; tracers; nitrous oxide; methane; second harmonic spectroscopy;
D O I
10.1016/S1386-1425(02)00048-3
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
We describe here a new instrument for the simultaneous, in situ measurement of the stratospheric tracer molecules, nitrous oxide (N2O) and methane (CH4). Argus is unique in its small size making it well suited for limited payload atmospheric research platforms. Argus employs second harmonic spectroscopy using tunable lead-salt diode lasers emitting in the mid-infrared. We first explain the Argus design philosophy followed by detailed descriptions of the instrument's optical, mechanical, and thermal sub-systems. Argus employs an in-flight calibration system providing real time calibrations and tightly constrained uncertainty estimates of the returned data. Data analysis is carried out using non-linear least-squares model fits to the acquired second harmonic spectra. A sampling of Argus data acquired on a recent stratospheric research campaign in the Arctic winter is presented. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:2329 / 2345
页数:17
相关论文
共 18 条
[1]   SPECTRUM LINE PROFILES - VOIGT FUNCTION [J].
ARMSTRONG, BH .
JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 1967, 7 (01) :61-+
[2]  
BUSCH KW, 1999, CAVITY RINGDOWN SPEC
[3]   LARGE LOSSES OF TOTAL OZONE IN ANTARCTICA REVEAL SEASONAL CLOX/NOX INTERACTION [J].
FARMAN, JC ;
GARDINER, BG ;
SHANKLIN, JD .
NATURE, 1985, 315 (6016) :207-210
[4]   VERSATILE INTEGRATED TUNABLE DIODE-LASER SYSTEM FOR HIGH-PRECISION - APPLICATION FOR AMBIENT MEASUREMENTS OF OCS [J].
FRIED, A ;
DRUMMOND, JR ;
HENRY, B ;
FOX, J .
APPLIED OPTICS, 1991, 30 (15) :1916-1932
[5]  
GREENBLATT BJ, 2002, IN PRESS J GEOPHYS R
[6]   EFFICIENT METHOD FOR EVALUATION OF THE COMPLEX PROBABILITY FUNCTION - VOIGT FUNCTION AND ITS DERIVATIVES [J].
HUMLICEK, J .
JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 1979, 21 (04) :309-313
[7]  
HURST DF, 2002, IN PRESS J GEOPHYS R
[8]   ABSOLUTE LINE STRENGTHS IN NU-4, (CH4)-C-12 - A DUAL-BEAM DIODE-LASER SPECTROMETER WITH SWEEP INTEGRATION [J].
JENNINGS, DE .
APPLIED OPTICS, 1980, 19 (16) :2695-2700
[9]   ASTIGMATIC MIRROR MULTIPASS ABSORPTION CELLS FOR LONG-PATH-LENGTH SPECTROSCOPY [J].
MCMANUS, JB ;
KEBABIAN, PL ;
ZAHNISER, WS .
APPLIED OPTICS, 1995, 34 (18) :3336-3348
[10]   BALLOON-BORNE DIODE-LASER ABSORPTION SPECTROMETER FOR MEASUREMENTS OF STRATOSPHERIC TRACE SPECIES [J].
MENZIES, RT ;
WEBSTER, CR ;
HINKLEY, ED .
APPLIED OPTICS, 1983, 22 (17) :2655-2664