The sensitivity of motor response to nerve stimulation and paresthesia for nerve localization as evaluated by ultrasound

被引:165
作者
Perlas, Anahi [1 ]
Niazi, Ahtsham [1 ]
McCartney, Colin [1 ]
Chan, Vincent [1 ]
Xu, Daquan [1 ]
Abbas, Sherif [1 ]
机构
[1] Toronto Western Hosp, Dept Anesthesia & Pain Med, Toronto, ON M5T 2S8, Canada
关键词
ultra sonography; paresthesia; electrical stimulation; sensitivity;
D O I
10.1016/j.rapm.2006.05.017
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background and Objective: Seeking paresthesia and obtaining a motor response to an electrical stimulus are the two most common methods of nerve localization for the performance of peripheral-nerve blocks. However, these two endpoints do not always correlate, and the actual sensitivity and specificity of either method remains unknown. The objective of this study is to determine the sensitivity of paresthesia and motor response to electrical nerve stimulation as tools for nerve localization when a 22-gauge insulated needle is used for the performance of axillary-nerve block. Methods: After IRB approval and informed consent, 103 patients were enrolled. Real-time ultrasonography was used as the reference test. After needle-to-nerve contact was confirmed by ultrasonography, the patient was requested to report the presence of paresthesia, and a nerve stimulator was used to seek a motor response, with a stimulating current of 0.5 mA or less. Results: One patient was excluded from analysis because of protocol violation. Paresthesia was found to be 38.2% sensitive and motor response was 74.5% sensitive for detection of needle-to-nerve contact. Conclusion: The very different and relatively low sensitivity of either technique may explain, in part, the lack of correlation previously reported between the 2 endpoints.
引用
收藏
页码:445 / 450
页数:6
相关论文
共 14 条
[1]  
[Anonymous], USERS GUIDES MED LIT
[2]   Major complications of regional anesthesia in France - The SOS Regional Anesthesia Hotline Service [J].
Auroy, Y ;
Benhamou, D ;
Bargues, L ;
Ecoffey, C ;
Falissard, B ;
Mercier, F ;
Bouaziz, H ;
Samii, K .
ANESTHESIOLOGY, 2002, 97 (05) :1274-1280
[3]   Relationship between evoked motor response and sensory paresthesia in interscalene brachial plexus block [J].
Bollini, CA ;
Urmey, WF ;
Vascello, L ;
Cacheiro, F .
REGIONAL ANESTHESIA AND PAIN MEDICINE, 2003, 28 (05) :384-388
[4]  
Capdevila X, 2004, Acta Anaesthesiol Belg, V55 Suppl, P33
[5]   Paresthesia but no motor response: What's going on? [J].
Casati, A ;
Chelly, JE ;
Lang, SA ;
Fanelli, G .
ANESTHESIOLOGY, 2003, 98 (02) :586-586
[6]   Nerve localization - Seek but not so easy to find? [J].
Chan, VWS .
REGIONAL ANESTHESIA AND PAIN MEDICINE, 2002, 27 (03) :245-248
[7]   What is the relationship between paresthesia and nerve stimulation for axillary brachial plexus block? [J].
Choyce, A ;
Chan, VWS ;
Middleton, WJ ;
Knight, PR ;
Peng, P ;
McCartney, CJL .
REGIONAL ANESTHESIA AND PAIN MEDICINE, 2001, 26 (02) :100-104
[8]  
GREENBLATT GM, 1962, ANESTH ANALG, V41, P599
[9]   Peripheral nerve stimulators: Cracking the code - One at a time [J].
Hadzic, A .
REGIONAL ANESTHESIA AND PAIN MEDICINE, 2004, 29 (03) :185-188
[10]   Ultrasonographic guidance improves sensory block and onset time of three-in-one blocks [J].
Marhofer, P ;
Schrogendorfer, K ;
Koinig, H ;
Kapral, S ;
Weinstabl, C ;
Mayer, N .
ANESTHESIA AND ANALGESIA, 1997, 85 (04) :854-857