Assessment of elbow joint kinematics in passive motion by electromagnetic motion tracking

被引:72
作者
Bottlang, M
Madey, SM
Steyers, CM
Marsh, JL
Brown, TD
机构
[1] Univ Iowa, Dept Biomed Engn, Iowa City, IA 52242 USA
[2] Univ Iowa, Dept Orthopaed Surg, Iowa City, IA 52242 USA
[3] Legacy Clin Res & Technol Ctr, Biomech Lab, Portland, OR USA
[4] Legacy Emanuel Hosp, Dept Trauma Surg, Portland, OR USA
关键词
D O I
10.1002/jor.1100180206
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This research provides a detailed analysis of the kinematics of passive elbow motion. It quantifies how closely humeroulnar kinematics approximates rotation around a fixed axis. The results are clinically relevant for emerging treatment modalities that impose an artificial hinge to the elbow joint, such as total elbow arthroplasty and articulated external fixation. In a cadaveric study of seven specimens, we quantified ulnar rotation around the humerus in terms of instantaneous screw displacement axes calculated from electromagnetic motion-tracking source data. This methodology enabled description of the complex excursion of the elbow axis in terms of translation and orientation changes of the screw displacement axes over the range of motion. Furthermore, we analyzed the envelope of joint laxity for elbow motion under applied small varus and valgus moments. In addition, radiographic landmarks of clinical utility for axis location were evaluated by visualizing the elbow's radiographic appearance when viewed from along the calculated best-fit (average) rotation axis. Over the normal range of elbow motion, the screw displacement axis varied 2.6-5.7 degrees in orientation and 1.4-2.0 mm in translation. All instantaneous rotation axes nearly intersected on the medial facet of the trochlea. The breadth of the envelope of varus-valgus joint laxity was greatest within the initial 40 degrees of flexion and decreased by a factor of approximately two for flexion angles exceeding 100 degrees.
引用
收藏
页码:195 / 202
页数:8
相关论文
共 20 条
[1]   APPLICATION OF A MAGNETIC TRACKING DEVICE TO KINESIOLOGIC STUDIES [J].
AN, KN ;
JACOBSEN, MC ;
BERGLUND, LJ ;
CHAO, EYS .
JOURNAL OF BIOMECHANICS, 1988, 21 (07) :613-&
[2]   MUSCLES ACROSS THE ELBOW JOINT - A BIOMECHANICAL ANALYSIS [J].
AN, KN ;
HUI, FC ;
MORREY, BF ;
LINSCHEID, RL ;
CHAO, EY .
JOURNAL OF BIOMECHANICS, 1981, 14 (10) :659-+
[3]  
Beggs JS., 1983, KINEMATICS
[4]   Factors influencing accuracy of screw displacement axis detection with a DC-based electromagnetic tracking system [J].
Bottlang, M ;
Marsh, JL ;
Brown, TD .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1998, 120 (03) :431-435
[5]  
Bottlang M, 1999, T ORTHOP RES SOC, V24, P494
[6]  
BOTTLANG M, 1999, T ORTHOP RES SOC, V24, P367
[7]  
BOTTLANG M, 1998, T 22 AM SOC BIOM, P521
[8]  
DELAND JT, 1987, CLIN ORTHOP RELAT R, P303
[9]  
Fischer O, 1911, HDB ANATOMIE MECH GE, V2, P299
[10]   KINEMATICS AND STABILITY OF THE NORWAY ELBOW - A CADAVERIC STUDY [J].
KING, GJW ;
ITOI, E ;
RISUNG, F ;
NIEBUR, GL ;
MORREY, BF ;
AN, KN .
ACTA ORTHOPAEDICA SCANDINAVICA, 1993, 64 (06) :657-663