Pulsed near-infrared photoacoustic spectroscopy of blood

被引:19
作者
Laufer, J [1 ]
Elwell, C [1 ]
Delpy, D [1 ]
Beard, P [1 ]
机构
[1] Univ Coll London, Dept Med Phys & Bioengn, London WC1E 6JA, England
来源
PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING | 2004年 / 5320卷
关键词
D O I
10.1117/12.531159
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The aim of this study was to use pulsed near infrared photoacoustic spectroscopy to determine the oxygen saturation (SO2) of a saline suspension of red blood cells in vitro. The photoacoustic measurements were made in a cuvette which formed part of a larger circuit through which the red blood cell suspension was circulated. Oxygen saturation of the red blood cell suspension was altered between 2-3% to 100% in step increments using a membrane oxygenator and at each increment an independent measurement of oxygen saturation was made using a co-oximeter. An optical parametric oscillator laser system provided nanosecond excitation pulses at a number of wavelengths in the near-infrared spectrum (740-1040nm) which were incident on the cuvette. The resulting acoustic signals were detected using a broadband (15MHz) Fabry-Perot polymer film transducer. The optical transport coefficient and amplitude were determined from the acoustic signals as a function of wavelength. These data were then used to calculate the relative concentrations of oxy- and deoxyhaemoglobin, using their known specific absorption coefficients and an empirically determined wavelength dependence of optical scattering over the wavelength range investigated. From this, the oxygen saturation of the suspension was derived with an accuracy of +/-5% compared to the co-oximeter SO2 measurements.
引用
收藏
页码:57 / 68
页数:12
相关论文
共 11 条
[1]   Interrogation of free-space Fabry-Perot sensing interferometers by angle tuning [J].
Beard, PC .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2003, 14 (11) :1998-2005
[2]   Transduction mechanisms of the Fabry-Perot polymer film sensing concept for wideband ultrasound detection [J].
Beard, PC ;
Pérennès, F ;
Mills, TN .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1999, 46 (06) :1575-1582
[3]  
Beck J.V., 1977, PARAMETER ESTIMATION
[4]   Optoacoustic technique for noninvasive monitoring of blood oxygenation: a feasibility study [J].
Esenaliev, RO ;
Larina, IV ;
Larin, KV ;
Deyo, DJ ;
Motamedi, M ;
Prough, DS .
APPLIED OPTICS, 2002, 41 (22) :4722-4731
[5]   Local determination of hemoglobin concentration and degree of oxygenation in tissue by pulsed photoacoustic spectroscopy [J].
Fainchtein, R ;
Stoyanov, BJ ;
Murphy, JC ;
Wilson, DA ;
Hanley, DF .
BIOMEDICAL OPTOACOUSTICS, 2000, 3916 :19-33
[6]   A scattering phase function for blood with physiological haematocrit [J].
Hammer, M ;
Yaroslavsky, AN ;
Schweitzer, D .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (03) :N65-N69
[7]   Photothermal determination of optical coefficients of tissue phantoms using an optical fibre probe [J].
Laufer, JG ;
Beard, PC ;
Walker, SP ;
Mills, TN .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (10) :2515-2530
[8]   Spectral optoacoustic imaging using a scanning transducer [J].
Paltauf, G ;
Köstli, KP ;
Frauchiger, D ;
Frenz, M .
HYBRID AND NOVEL IMAGING AND NEW OPTICAL INSTRUMENTATION FOR BIOMEDICAL APPLICATIONS, 2001, 4434 :81-88
[9]   Optical properties of circulating human blood in the wavelength range 400-2500 NM [J].
Roggan, A ;
Friebel, M ;
Dörschel, K ;
Hahn, A ;
Müller, G .
JOURNAL OF BIOMEDICAL OPTICS, 1999, 4 (01) :36-46
[10]  
SVATEEVA E, 2002, P SOC PHOTO-OPT INS, V4618, P65