Positive (1→3)-β-D-glucan in blood components and release of (1→3)-β-D-glucan, from depth-type membrane filters for blood processing

被引:100
作者
Usami, M
Ohata, A
Horiuchi, T
Nagasawa, K
Wakabayashi, T
Tanaka, S
机构
[1] Kobe Univ, Sch Med, Fac Hlth Sci, Div Surg Metab,Suma Ku, Kobe, Hyogo 65401, Japan
[2] Univ E Asia, Grad Sch, Div Life Sci, Shimonoseki, Yamaguchi, Japan
[3] Univ E Asia, Dept Food Sci, Shimonoseki, Yamaguchi, Japan
[4] SRL Inc, Tokyo, Japan
[5] Seikagaku Corp, Tokyo, Japan
关键词
D O I
10.1046/j.1537-2995.2002.00162.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: The false-positive elevation of plasma (1-->3)-beta-D-glucan level, a serodiagnostic test for deep-seated mycosis, is suspected in patients administered with blood components. STUDY DESIGN AND METHODS: (1-->3)-beta-D-Glucan and endotoxin levels in blood components consisting of 12 albumins, 8 immunoglobulins, and 3 blood coagulation factors were measured by fungal infection tests (Fungitec G-test, Seikagaku Co.; the Wako WB003 test, Wako Pure Chemical Industries; and the Endospec ES test, Seikagaku Co.). In vitro release of (1-->3)-beta-D-glucan from the depth-type filters made by cellulose membrane to process blood components was analyzed through an in vitro filtration process as a source of (1-->3)-beta-D-glucan in blood components. RESULTS: The amounts of (1-->3)-beta-D-glucan in blood components ranged from 0 to 7510 pg per mL in the Fungitec G-test, with wide variations among brands. The positive rates over 20 pg per mL were 75 percent in albumin solutions, 40 percent in blood coagulation factors, and 63 percent in immunoglobulin solutions. (1-->3)-beta-D-Glucan levels released from the five depth filters ranged from 5 to 2516 pg per mL. The (1--> 3)-beta-D-glucan level in filtration fluid was decreased by rinsing with distilled water, but rebounded again during the albumin filtration process. CONCLUSION: Depth filters are considered the source of (1-->3)-beta-D-glucan content in some blood components.
引用
收藏
页码:1189 / 1195
页数:7
相关论文
共 20 条
  • [1] ACTIVATION OF LIMULUS COAGULATION FACTOR-G BY SEVERAL (1-]3)-BETA-D-GLUCANS - COMPARISON OF THE POTENCY OF GLUCANS WITH IDENTICAL DEGREE OF POLYMERIZATION BUT DIFFERENT CONFORMATIONS
    AKETAGAWA, J
    TANAKA, S
    TAMURA, H
    SHIBATA, Y
    SAITO, H
    [J]. JOURNAL OF BIOCHEMISTRY, 1993, 113 (06) : 683 - 686
  • [2] Hossain MA, 1997, J CLIN LAB ANAL, V11, P73, DOI 10.1002/(SICI)1098-2825(1997)11:2&lt
  • [3] 73::AID-JCLA1&gt
  • [4] 3.0.CO
  • [5] 2-L
  • [6] FALSE-POSITIVE RESULT IN LIMULUS TEST CAUSED BY LIMULUS AMEBOCYTE LYSATE-REACTIVE MATERIAL IN IMMUNOGLOBULIN PRODUCTS
    IKEMURA, K
    IKEGAMI, K
    SHIMAZU, T
    YOSHIOKA, T
    SUGIMOTO, T
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1989, 27 (09) : 1965 - 1968
  • [7] INOUE Y, 1995, INTERNAL MED, V34, P485, DOI 10.2169/internalmedicine.34.485
  • [8] AN EVALUATION OF SERODIAGNOSTIC TESTS IN PATIENTS WITH CANDIDEMIA - BETA-GLUCAN, MANNAN, CANDIDA ANTIGEN BY CAND-TEC AND D-ARABINITOL
    KOHNO, S
    MITSUTAKE, K
    MAESAKI, S
    YASUOKA, A
    MIYAZAKI, T
    KAKU, M
    KOGA, H
    HARA, K
    [J]. MICROBIOLOGY AND IMMUNOLOGY, 1993, 37 (03) : 207 - 212
  • [9] Miura T, 1997, BIOL PHARM BULL, V20, P1103
  • [10] G-TEST, A NEW DIRECT METHOD FOR DIAGNOSIS OF CANDIDA INFECTION - COMPARISON WITH ASSAYS FOR BETA-GLUCAN AND MANNAN ANTIGEN IN A RABBIT MODEL OF SYSTEMIC CANDIDIASIS
    MIYAZAKI, T
    KOHNO, S
    KOGA, H
    KAKU, M
    MITSUTAKE, K
    MAESAKI, S
    YASUOKA, A
    HARA, K
    TANAKA, S
    TAMURA, H
    [J]. JOURNAL OF CLINICAL LABORATORY ANALYSIS, 1992, 6 (05) : 315 - 318