Biosensors for life quality -: Design, development and applications

被引:178
作者
Castillo, J
Gáspár, S
Leth, S
Niculescu, M
Mortari, A
Bontidean, I
Soukharev, V
Dorneanu, SA
Ryabov, AD
Csöregi, E
机构
[1] Lund Univ, Dept Biotechnol, S-22100 Lund, Sweden
[2] Moscow MV Lomonosov State Univ, Dept Chem, Moscow 119899, Russia
[3] Carnegie Mellon Univ, Dept Chem, Pittsburgh, PA 15213 USA
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2004年 / 102卷 / 02期
关键词
biosensor; life quality; mediators; biomedical application; food quality; environment;
D O I
10.1016/j.snb.2004.04.084
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Biosensors, combining a selective biological recognition element and a sensitive transducer, are versatile analytical tools applied more and more in different fields, such as medicine, food quality and safety control, and environment pollution monitoring. They are expected to play an increasingly important role in the improvement of life quality. In this context, the present work covers recent approaches in design and development of biosensors applied for analysis of real samples of medical, environmental or industrial relevance. The described sensors meet the sensitivity, selectivity, and response time required by their applications. Moreover, they are designed to avoid contamination of the monitored systems with undesirable components and to minimise the damage of living organisms (when it comes to in vivo monitoring). (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:179 / 194
页数:16
相关论文
共 117 条
[1]   Development of an amperometric sulfite biosensor based on sulfite oxidase with cytochrome c, as electron acceptor, and a screen-printed transducer [J].
Abass, AK ;
Hart, JP ;
Cowell, D .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 62 (02) :148-153
[2]   Biosensors for in vivo glucose measurement: can we cross the experimental stage [J].
Abel, PU ;
von Woedtke, T .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (11-12) :1059-1070
[3]   A mushroom (Agaricus bisporus) tissue homogenate based alcohol oxidase electrode for alcohol determination in serum [J].
Akyilmaz, E ;
Dinckaya, E .
TALANTA, 2000, 53 (03) :505-509
[4]  
Anderson JL, 1996, ANAL CHEM, V68, pR379, DOI 10.1021/a1960015y
[5]   RECENT ADVANCES IN THE DEVELOPMENT AND ANALYTICAL APPLICATIONS OF BIOSENSING PROBES [J].
ARNOLD, MA ;
MEYERHOFF, ME .
CRC CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 1988, 20 (03) :149-196
[6]   Implantation of a refillable glucose monitoring-telemetry device [J].
Atanasov, P ;
Yang, S ;
Salehi, C ;
Ghindilis, AL ;
Wilkins, E ;
Schade, D .
BIOSENSORS & BIOELECTRONICS, 1997, 12 (07) :669-680
[7]   Whole cell biosensors - electrochemical and optical approaches to ecotoxicity testing [J].
Bentley, A ;
Atkinson, A ;
Jezek, J ;
Rawson, DM .
TOXICOLOGY IN VITRO, 2001, 15 (4-5) :469-475
[8]   Instrumentation for direct capacitive biosensors [J].
Berggren, C ;
Bjarnason, B ;
Johansson, G .
INSTRUMENTATION SCIENCE & TECHNOLOGY, 1999, 27 (02) :131-139
[9]   Capacitance measurements of antibody-antigen interactions in a flow system [J].
Berggren, C ;
Johansson, G .
ANALYTICAL CHEMISTRY, 1997, 69 (18) :3651-3657
[10]   Online and in situ monitoring of environmental pollutants:: electrochemical biosensing of cadmium [J].
Biran, I ;
Babai, R ;
Levcov, K ;
Rishpon, J ;
Ron, EZ .
ENVIRONMENTAL MICROBIOLOGY, 2000, 2 (03) :285-290