Diagnostic significance of free salivary testosterone measurement using a direct luminescence immunoassay in healthy men and in patients with disorders of androgenic status

被引:37
作者
Goncharov, Nikolai
Katsya, Gulinara
Dobracheva, Anna
Nizhnik, Alexander
Kolesnikova, Galina
Herbst, Victor
Westermann, Juergen
机构
[1] Natl Ctr Endocrinol, Moscow 117036, Russia
[2] IBL GmbH, D-22335 Hamburg, Germany
关键词
free testosterone; saliva; blood;
D O I
10.1080/13685530600713060
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The accurate measurement of testosterone remains a challenge. The determination of the blood testosterone concentrations in serum by conventional immunoassays is inaccurate in men and even more so in females and children. A new luminescence enzyme immunoassay (LIA) has been developed and validated. The high analytical (8.7 pmol/L) and functional (17.3 pmol/ L) sensitivity allows the quantification of the very low concentration in saliva, as well as in serum, after 1/40 dilution. This study measured salivary testosterone levels and compared the results with the free levels calculated from total testosterone and sex hormone-binding globulin in eugonadal and hypogonadal men. Salivary testosterone concentrations in healthy men in morning hours were 369 pmol/L (mean), range 263-544 pmol/L, which was statistically significantly higher than that in men with androgen deficiency, 215 pmol/L (mean), range 51-249 pmol/L. Repetitive determination of free testosterone concentrations in saliva (once a week for 5 weeks) showed high stability of results over time, with coefficient of variation 9% (range 5-23%). In this study we showed that free salivary testosterone levels in morning samples correlated well with calculated free testosterone in blood, both in healthy men (R=0.754, P=0.001), and in patients with androgen deficiency (R=0.889, P = 0.0001), though in cases with very low testosterone, salivary concentrations were systematically higher than calculated free testosterone levels in blood.
引用
收藏
页码:111 / 122
页数:12
相关论文
共 17 条
[1]  
ALBRECHT S, 1997, J LAB MED, V21, P191
[2]  
Corradi Gyula, 1998, Orvosi Hetilap, V139, P2021
[3]  
Goncharov N, 2005, Aging Male, V8, P194, DOI 10.1080/13685530500355566
[4]  
JAMES VHT, 1982, IMMUNOASSAYS STEROID, P193
[5]   STEROID ASSAYS IN SALIVA - A METHOD TO DETECT PLASMATIC CONTAMINATIONS [J].
LAC, G ;
LAC, N ;
ROBERT, A .
ARCHIVES INTERNATIONALES DE PHYSIOLOGIE DE BIOCHIMIE ET DE BIOPHYSIQUE, 1993, 101 (05) :257-262
[6]  
Landon J, 1982, IMMUNOASSAYS STEROID, P47
[7]   Editorial: Serum testosterone assays - Accuracy matters [J].
Matsumoto, AM ;
Bremner, WJ .
JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2004, 89 (02) :520-524
[8]   Measurement of free testosterone in normal women and women with androgen deficiency: Comparison of methods [J].
Miller, KK ;
Rosner, W ;
Lee, H ;
Hier, J ;
Sesmilo, G ;
Schoenfeld, D ;
Neubauer, G ;
Klibanski, A .
JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2004, 89 (02) :525-533
[9]  
READ G, 1982, IMMUNOASSAYS STEROID, P215
[10]   An extraordinarily inaccurate assay for free testosterone is still with us [J].
Rosner, W .
JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2001, 86 (06) :2903-2903