A computer generated interactive transurethral prostatic resection simulator

被引:41
作者
Ballaro, A
Briggs, T
Garcia-Montes, F
MacDonald, D
Emberton, M
Mundy, AR
机构
[1] UCL, Inst Urol & Nephrol, London, England
[2] UCL, Dept Med Graph, London, England
关键词
prostatectomy; endoscopy; computer simulation;
D O I
10.1016/S0022-5347(05)68184-0
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Purpose: We developed a computer generated model of the prostate gland and an interactive simulator for use in training urologists in transurethral resection of the prostate. Materials and Methods: Software was developed on a standard personal computer which allowed images of the lumen of the prostatic urethra and resectoscope loop to be generated and interacted with using a magnetic position sensor input device attached to a dummy resectoscope. Results: An anatomically accurate computer model of the prostate was generated at low cost which permitted user interaction and which simulated key elements of transurethral prostatic resection. Conclusions: Although not a substitute for learning transurethral prostatic resection on patients, the simulator enabled the user to become familiar with the technique of transurethral prostatic resection in the absence of time constraints and without risk to patients. The simulator may become an important tool in training and assessing surgeon competency, and may reduce the costs of training. Further development is needed to refine the transurethral prostatic resection simulator and expand its surgical range.
引用
收藏
页码:1633 / 1635
页数:3
相关论文
共 16 条
[1]  
Ahmed M, 1997, BRIT J UROL, V80, P46
[2]   VIRTUAL-REALITY AND LAPAROSCOPIC SURGERY [J].
COLEMAN, J ;
NDUKA, CC ;
DARZI, A .
BRITISH JOURNAL OF SURGERY, 1994, 81 (12) :1709-1711
[3]   Assessing operative skill - Needs to become more objective [J].
Darzi, A ;
Smith, S ;
Taffinder, N .
BRITISH MEDICAL JOURNAL, 1999, 318 (7188) :887-888
[4]   VIRTUAL-REALITY IN MEDICAL-TRAINING [J].
DUNKLEY, P .
LANCET, 1994, 343 (8907) :1218-1218
[5]   The economics of urologic practice in the twenty-first century [J].
Holtgrewe, HL .
UROLOGIC CLINICS OF NORTH AMERICA, 1998, 25 (01) :1-+
[6]   The development of a multimedia teaching program for fiberoptic intubation [J].
Katz, DB ;
Pearlman, JD ;
Popitz, M ;
Shorten, GD .
JOURNAL OF CLINICAL MONITORING, 1997, 13 (05) :287-291
[7]   The Karlsruhe endoscopic surgery trainer as an example for virtual reality in medical education [J].
Kuhnapfel, UG ;
Kuhn, C ;
Hubner, M ;
Krumm, HG ;
Maass, H ;
Neisius, B .
MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 1997, 6 (02) :122-125
[8]  
Kuppersmith RB, 1996, ARCH OTOLARYNGOL, V122, P1297
[9]   APPLICATIONS OF VIRTUAL-REALITY TO SURGERY [J].
MCGOVERN, KT .
BRITISH MEDICAL JOURNAL, 1994, 308 (6936) :1054-1055
[10]  
Mundy AR, 1998, BRIT J UROL, V82, P476