Three-dimensional ultrasound detection of abnormally located intrauterine contraceptive devices which are a source of pelvic pain and abnormal bleeding

被引:82
作者
Benacerraf, B. R. [1 ,2 ,3 ,4 ,5 ]
Shipp, T. D. [2 ,4 ,5 ]
Bromley, B. [2 ,4 ,5 ]
机构
[1] Brigham & Womens Hosp, Dept Radiol, Boston, MA 02115 USA
[2] Brigham & Womens Hosp, Dept OB GYN, Boston, MA 02115 USA
[3] Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
[4] Massachusetts Gen Hosp, Dept OB GYN, Boston, MA 02114 USA
[5] Harvard Univ, Med Scbool, Boston, MA USA
关键词
3D ultrasound; IUD; pelvic pain; SONOGRAPHY; UTERUS;
D O I
10.1002/uog.6421
中图分类号
O42 [声学];
学科分类号
070206 [声学];
摘要
Objective To determine whether intrauterine contraceptive devices (IUDs) that are located abnormally within the myometrium or cervix cause a higher incidence of pelvic pain and abnormal bleeding compared with normally positioned devices. Methods Over a period of 9 months, all patients with an IUD presenting at our unit for two-dimensional pelvic ultrasound underwent a three-dimensional (3D) volume reconstruction of the coronal view, to visualize the entire IUD within the cavity. The IUD was deemed malpositioned if any part extended past the cavity, into the myometrium or cervix. The indications for ultrasound were recorded at presentation for the exam. The presenting symptoms of patients with an abnormally located IUD were compared with those with normally positioned ones. Results Among 167 consecutive patients with an IUD evaluated using the 3D reconstructed coronal view, 28 (16.8%) bad an IUD with side arms abnormally located within the myometrium. The abnormal positioning of the IUD arms was only detected using the 3D coronal view. A higher proportion of patients with an abnormally located IUD presented with bleeding (35.7%) or pain (39.3%) compared with those with normally positioned IUDs (15.1% with bleeding and 19.4% with pain) (P = 0.02 and 0.03, respectively). Seventy-five Percent of Patients with an abnormally located IUD presented with bleeding or pain compared with 34.5% of those whose IUD was normally placed (P = 0.0001). Twenty of 21 patients with an abnormally located IUD presenting with pelvic pain or bleeding reported improvement in their symptoms after IUD removal. Conclusion A 3D coronal view of the uterus is useful in the visualization of IUDs. The coronal view showing the entire device and its position within the uterus may help in identifying the cause of pelvic pain and bleeding in patients with an embedded IUD. Copyright (c) 2009 ISUOG. Published by John Wiley & Sons, Ltd.
引用
收藏
页码:110 / 115
页数:6
相关论文
共 11 条
[1]
The Z technique: An easy approach to the display of the midcoronal plane of the uterus in volume sonography [J].
Abuhamad, Alfred Z. ;
Singleton, Stephanie ;
Zhao, Yueqin ;
Bocca, Silvina .
JOURNAL OF ULTRASOUND IN MEDICINE, 2006, 25 (05) :607-612
[2]
Adeyemi A S, 2008, Niger J Med, V17, P67
[3]
Three-dimensional sonography of the endometrium and adjacent myometrium - Preliminary observations [J].
Andreotti, Rochelle F. ;
Fleischer, Arthur C. ;
Mason, Lawrence E., Jr. .
JOURNAL OF ULTRASOUND IN MEDICINE, 2006, 25 (10) :1313-1319
[4]
Three-dimensional ultrasonography in gynecology - Technical aspects and clinical applications [J].
Bega, G ;
Lev-Toaff, AS ;
O'Kane, P ;
Becker, E ;
Kurtz, AB .
JOURNAL OF ULTRASOUND IN MEDICINE, 2003, 22 (11) :1249-1269
[5]
Which patients benefit from a 3D reconstructed coronal view of the uterus added to standard routine 2D pelvic sonography? [J].
Benacerraf, Beryl R. ;
Shipp, Thomas D. ;
Bromley, Bryann .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 190 (03) :626-629
[6]
BonillaMusoles F, 1996, J CLIN ULTRASOUND, V24, P263, DOI 10.1002/(SICI)1097-0096(199606)24:5<263::AID-JCU6>3.0.CO
[7]
2-C
[8]
Intrauterine device localization by three-dimensional transvaginal sonography [J].
Lee, A ;
Eppel, W ;
Sam, C ;
Kratochwil, A ;
Deutinger, J ;
Bernaschek, G .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 1997, 10 (04) :289-292
[9]
Imaging of intrauterine contraceptive devices [J].
Peri, Nagamani ;
Graham, David ;
Levine, Deborah .
JOURNAL OF ULTRASOUND IN MEDICINE, 2007, 26 (10) :1389-1401
[10]
TRENDS IN POPULATION AND CONTRACEPTION [J].
SEGAL, SJ .
ANNALS OF MEDICINE, 1993, 25 (01) :51-56