Analysis of noise-injection networks for interferometric-radiometer calibration

被引:33
作者
Corbella, I [1 ]
Camps, A [1 ]
Torres, F [1 ]
Bará, J [1 ]
机构
[1] Univ Politecn Catalunya, ES-08034 Barcelona, Spain
关键词
calibration; interferometry; noisy networks; radiometry;
D O I
10.1109/22.842026
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The spatial resolution of current space-borne Earth observation radiometers is limited by the physical antenna aperture. This is especially critical at L-band, which exhibits high sensitivity to soil moisture and sea surface salinity. Interferometric radiometers (InR's) are currently being studied by several space agencies as a feasible alternative to overcome this problem. However, their calibration is a crucial issue since most techniques inherited from radio astronomy cannot be directly applied. Due to the large number of receiving channels, calibration techniques based on centralized noise injection from a single noise source will require a large and stable distribution network, which is technically very complex and unacceptable from the point-of-view of mass and volume. Procedures based on distributed noise injection from a set of noise sources through smaller distribution networks have been recently proposed by the authors as an alternative to alleviate these technological problems. In this paper, the analysis of these networks, the impact of the noise generated by the network losses on the calibration, and the impact of front-end reradiated noise are analyzed, Finally, the optimum circuit topologies and tolerances to which these networks have to be characterized in order to achieve the required calibration are derived. These configurations are formed by cascading basic 1:2 and 1:3 isolated power splitters. Isolators at receivers' inputs have to be included in order to minimize offsets originated from the correlation of reradiation of receiver noise, It has been found that, in order to satisfy the calibration requirements of InR's, the S-parameters of the ensemble noise-injection network plus isolators have to be known to within 0.025-0.050 dB in amplitude and 0.5 degrees in phase, and their physical temperature known to within 0.5 degrees C.
引用
收藏
页码:545 / 552
页数:8
相关论文
共 13 条
[1]  
[Anonymous], 1997, ESA B
[2]  
BOSMA H, 1967, PHILIPS RES REP S, V10
[3]   Impact of antenna errors on the radiometric accuracy of large aperture synthesis radiometers [J].
Camps, A ;
Bara, J ;
Torres, F ;
Corbella, I ;
Romeu, J .
RADIO SCIENCE, 1997, 32 (02) :657-668
[4]   The processing of hexagonally sampled signals with standard rectangular techniques: Application to 2-D large aperture synthesis interferometric radiometers [J].
Camps, A ;
Bara, J ;
Sanahuja, IC ;
Torres, F .
IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 1997, 35 (01) :183-190
[5]  
CAMPS A, 1997, ELECTRON LETT, V33, P813
[6]  
Camps Carmona A. J., 1996, Application of Interferometric Radiometry to Earth Observation
[7]  
CORBELLA I, 1998, P SPIE C SENS SYST N, V4, P359
[8]   INTERFEROMETRIC SYNTHETIC APERTURE MICROWAVE RADIOMETRY FOR THE REMOTE-SENSING OF THE EARTH [J].
RUF, CS ;
SWIFT, CT ;
TANNER, AB ;
LEVINE, DM .
IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 1988, 26 (05) :597-611
[9]  
Thompson A. R., 1986, INTERFEROMETRY SYNTH
[10]   On-board phase and modulus calibration of large aperture synthesis radiometers: Study applied to MIRAS [J].
Torres, F ;
Camps, A ;
Bara, J ;
Corbella, I ;
Ferrero, R .
IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 1996, 34 (04) :1000-1009