Direct plasma liquid chromatographic-tandem mass spectrometric analysis of granisetron and its 7-hydroxy metabolite utilizing internal surface reversed-phase guard columns and automated column switching devices

被引:53
作者
Boppana, VK
MillerStein, C
Schaefer, WH
机构
[1] Dept. Drug Metab. and Pharmacokin., SmithKline Beecham Pharmaceuticals, King of Prussia, PA 19406
来源
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS | 1996年 / 678卷 / 02期
关键词
granisetron; 7-hydroxygranisetron;
D O I
10.1016/0378-4347(95)00480-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An alternative on-line automated sample enrichment technique useful for the direct determination of various drugs and their metabolites in plasma is described for rapid development of highly sensitive and selective liquid chromatographic methods using mass spectrometric detection. The method involves direct injection of plasma onto an internal surface reversed-phase (ISRP) guard column, washing the proteins from the column to waste with aqueous acetonitrile, and backflushing the analytes onto a reversed-phase octyl silica column using switching valves. The analytes were detected using a tandem mass spectrometer operated in selected reaction monitoring (SRM) mode using atmospheric pressure chemical ionization (APCI). Use of two ISRP guard columns in parallel configuration allowed alternate injections of plasma samples on these columns for sample enrichment and shortened the column equilibration and LC-MS-MS analysis times, thereby increasing the sample throughput. The total run time, including both sample enrichment and chromatography, was about 6 min. Using this technique, an analytical method was developed for the quantitation of granisetron and its active 7-hydroxy metabolite in dog plasma. Granisetron is a selective 5-HT3 receptor antagonist used in the prevention and treatment of cytostatic induced nausea and vomiting. Recovery of the analytes was quantitative and the method displayed excellent linearity over the concentration ranges tested. Results from a three day validation study for both compounds demonstrated excellent precision (1.3-8.7%) and accuracy (93-105%) across the calibration range of 0.1 to 50 ng/ml using an 80 mu l plasma sample. The automated method described here was simple, reliable and economical. This on-line approach using ISRP columns and column switching with LC-MS-MS is applicable for the quantification of other pharmaceuticals in pharmacokinetic studies in animals and humans which require high sensitivity.
引用
收藏
页码:227 / 236
页数:10
相关论文
共 36 条
  • [1] ATHERTON ND, 1989, CLIN CHEM, V35, P975
  • [3] CARMICHAEL J, 1989, CANCER CHEMOTH PHARM, V24, P45
  • [4] THE SEROTONIN TYPE-3 RECEPTOR ANTAGONIST BRL-43694 AND NAUSEA AND VOMITING INDUCED BY CISPLATIN
    CARMICHAEL, J
    CANTWELL, BMJ
    EDWARDS, CM
    RAPEPORT, WG
    HARRIS, AL
    [J]. BRITISH MEDICAL JOURNAL, 1988, 297 (6641) : 110 - 111
  • [5] THE MEASUREMENT OF WARFARIN ENANTIOMERS IN SERUM USING COUPLED ACHIRAL CHIRAL, HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY (HPLC)
    CHU, YQ
    WAINER, IW
    [J]. PHARMACEUTICAL RESEARCH, 1988, 5 (10) : 680 - 683
  • [6] METABOLISM AND DISPOSITION OF C-14 GRANISETRON IN RAT, DOG AND MAN AFTER INTRAVENOUS AND ORAL DOSING
    CLARKE, SE
    AUSTIN, NE
    BLOOMER, JC
    HADDOCK, RE
    HIGHAM, FC
    HOLLIS, FJ
    NASH, M
    SHARDLOW, PC
    TASKER, TC
    WOODS, FR
    ALLEN, GD
    [J]. XENOBIOTICA, 1994, 24 (11) : 1119 - 1131
  • [7] CHARACTERIZATION OF INTERNAL SURFACE REVERSED-PHASE SILICA SUPPORTS FOR LIQUID-CHROMATOGRAPHY
    COOK, SE
    PINKERTON, TC
    [J]. JOURNAL OF CHROMATOGRAPHY, 1986, 368 (02): : 233 - 248
  • [8] A NON-EXTRACTION HPLC METHOD FOR THE SIMULTANEOUS DETERMINATION OF SERUM PARACETAMOL AND SALICYLATE
    DAWSON, CM
    WANG, TWM
    RAINBOW, SJ
    TICKNER, TR
    [J]. ANNALS OF CLINICAL BIOCHEMISTRY, 1988, 25 : 661 - 667
  • [9] MEASUREMENT OF 4-HYDROXYANISOLE IN SERUM BY DIRECT INJECTION HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    DAWSON, CM
    BELCHER, HJCR
    RAINBOW, SJ
    TICKNER, TR
    [J]. JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1990, 534 : 267 - 270
  • [10] THE SEMIPERMEABLE SURFACE, A NEW RESTRICTED ACCESS MEDIUM
    GLUNZ, LJ
    PERRY, JA
    INVERGO, B
    WAGNER, H
    SZCZERBA, TJ
    RATEIKE, JD
    GLUNZ, PW
    [J]. JOURNAL OF LIQUID CHROMATOGRAPHY, 1992, 15 (08): : 1361 - 1379